Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study
Real-World-Daten zur Häufigkeit von Flash-Glukosemonitoring und glykämischen Kennzahlen bei omanischen Diabetespatient:innen: vorläufige retrospektive Querschnittsstudie
Sultan Qaboos University Medical Journal · 10.01.2026 · 26 (1) · 29-35
DOI: 10.18295/2075-0528.2952 ↗Auf einen Blick
Bei 436 Diabetespatient:innen war häufigeres Scannen mit besserer glykämischer Kontrolle verbunden. Höhere Scanfrequenz ging mit höherem TIR und niedrigerem eA1c einher.
Fragestellung
Wie hängen Scanfrequenz beim Flash-Glukosemonitoring und glykämische Kennzahlen bei Diabetespatient:innen zusammen?
Methode
Retrospektive Querschnittsstudie an Diabetespatient:innen mit Flash-Glukosemonitoring in einem Krankenhaus in Maskat; Auswertung zwischen Januar 2022 und August 2023.
Ergebnisse
436 Patient:innen. Bei ≥12 Scans/Tag (Median 17) vs. ≤3 Scans/Tag: TIR 52,4 % vs. 34,8 %, Time-above-range 41,8 % vs. 57,0 %, eA1c 7,7 % vs. 9,0 %, Glukose-SD 70,22 mg/dL vs. 82,21 mg/dL. Kein signifikanter Zusammenhang mit Time-below-range oder Variationskoeffizient.
Schlussfolgerung der Autor:innen
Häufigeres Scannen mit FGM war mit besserer glykämischer Kontrolle bei omanischen Diabetespatient:innen assoziiert.
Kernaussagen
- Höhere Scanfrequenz war mit höherem TIR verbunden.
- eA1c und Time-above-range waren bei häufigerem Scannen niedriger.
- Kein signifikanter Zusammenhang mit Time-below-range oder Variationskoeffizient.
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Querschnittstudie in der Zeitschrift Sultan Qaboos University Medical Journal, online erschienen am 10.01.2026. Verfasst von Ammar Al-Mamari und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, College of Medicine and Health Sciences, Sultan Qaboos University, Muscat, Oman. Hauptthemen laut MEDLINE: Blood Glucose Self-Monitoring, Blood Glucose, Glycemic Control, Diabetes Mellitus. Der Volltext ist frei zugänglich (Open Access, CC BY-ND 4.0).
Themen: Diabetes mellitus
Abstract (Originalsprache)
Objectives
This study aimed to evaluate real-world glycaemic outcomes associated with flash glucose monitoring (FGM) use in patients with diabetes at Sultan Qaboos University Hospital, Muscat, Oman.
Methods
This retrospective cross-sectional study was conducted among diabetic patients using flash glucose monitoring between January 2022 and August 2023. Patients were grouped by scanning frequency, time-in-range (TIR) and estimated A1c (eA1c). Associations between scanning frequency and glycaemic metrics were analysed.
Results
A total of 436 patients were included in this study. Patients with higher scanning frequency (≥12 scans/day, median = 17) achieved greater TIR (52.4% versus 34.8%), lower time-above-range (41.8% versus 57.0%), lower eA1c (7.7% versus 9.0%) and lower glucose standard deviation (70.22 mg/dL versus 82.21 mg/dL) compared with those with the lowest scanning frequency (≤3 scans/day). No significant association was found between scanning frequency and time-below-range or glucose coefficient of variation.
Conclusion
Frequent FGM scanning was associated with improved glycaemic control in Omani diabetes patients, supporting its role in real-world diabetes management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Internal Medicine, College of Medicine and Health Sciences, Sultan Qaboos University, Muscat, Oman.
Zitieren
APA
Al-Mamari, A., Al Gharabi, S., Al Busaidy, M., & Al Futaisi, A. (2026). Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study. Sultan Qaboos University Medical Journal, 26(1), 29-35. https://doi.org/10.18295/2075-0528.2952
Vancouver
Al-Mamari A, Al Gharabi S, Al Busaidy M, Al Futaisi A. Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study. Sultan Qaboos University Medical Journal. 2026;26(1):29-35. doi:10.18295/2075-0528.2952
BibTeX
@article{AlMamari2026,
author = {Al-Mamari, Ammar and Al Gharabi, Sumaia and Al Busaidy, Merah and Al Futaisi, Abdulla},
title = {Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study},
journal = {Sultan Qaboos University Medical Journal},
year = {2026},
volume = {26},
number = {1},
pages = {29--35},
doi = {10.18295/2075-0528.2952}
}
EUVIMED