EUVIMEDOntdek EUVIMED
Open access · CC BY 4.0

Hypothermic Machine Perfusion in Deceased Donor Kidney Transplantation: Provider and Transplant Center Practices and Perspectives

Beatrice P Concepcion iD, Laura A Binari, Vasanthi Balaraman iD, Angie Nishio-Lucar, Anju Yadav iD, Ankita Patel iD, Kenneth J Woodside iD, Krista L Lentine iD, M Lee Sanders iD, Oluwafisayo O Adebiyi iD, Sabiha M Hussain iD, Shikha Mehta and 3 more

Clinical Transplantation · 2026

DOI: 10.1111/ctr.70637 ↗

At a glance

Journal article in Clinical Transplantation, 2026. Written by Beatrice P Concepcion and 14 co-authors. Institution: University of Chicago, Chicago, Illinois, USA. Major MEDLINE topics: Kidney Transplantation, Organ Preservation, Perfusion, Tissue Donors. 29 references. The full text is freely available (open access, CC BY 4.0).

SamenvattingSubjectsBibliografische gegevensCiteRelated studies

Abstract (original language)

Background

Hypothermic machine perfusion (HMP), an organ preservation technique used in deceased donor kidney transplantation, improves early outcomes compared to traditional static cold storage while also providing a loosely validated organ viability assessment.

Methods

We designed a survey to better understand the practices, perceptions, and barriers to utilization of HMP. Surgeons, nephrologists, and coordinators were invited to participate in the survey via email.

Results

Respondents (90% transplant surgeons) from 88 transplant centers which utilize HMP (35% of active kidney transplant centers) participated, representing 63% of total transplant volume in 2024. Respondents strongly agreed that HMP is helpful in kidney selection (92%), reduces delayed graft function (90%), and allows for scheduling flexibility (91%). A majority (74%) answered that the Organ Procurement Organization (OPO exclusively pumps kidneys. The most cited barrier to HMP use was OPO refusal (58%). Thresholds for resistance and flow varied widely with over 2/3 of respondents citing a specified acceptable cut‐off. Most respondents answered “sometimes” (60%) or “yes” (20%) that they would decline a kidney if HMP could not be accomplished for a kidney they wished to be pumped. Perceived pitfalls were underutilization of kidneys due to incorrect or inaccurate perfusion parameters, logistical challenges and costs of pumping, inexperience and technical difficulties leading to organ or vasculature injury, and lack of standardization in practice.

Conclusions

HMP is used as a tool to assess organ viability and to overcome logistical hurdles by improving flexibility in operative timing. OPOs play a critical role in the ability to perform HMP.

Subjects

MeSH terms (MEDLINE)

Kidney TransplantationOrgan PreservationPerfusionTissue DonorsTissue and Organ ProcurementHypothermia, InducedPractice Patterns, Physicians'HumansSurveys and QuestionnairesPrognosisGraft SurvivalFollow-Up StudiesCadaver

Author keywords

cold ischemia timedeceased donor kidneysdelayed graft functionkidney transplantationmachine perfusionorgan procurement

Authors and institutions

  • University of Chicago, Chicago, Illinois, USA.
  • Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • University of Tennessee Health Science Center, Memphis, Tennessee, USA.
  • University of Virginia, Charlottesville, Virginia, USA.
  • Johns Hopkins University, Baltimore, Maryland, USA.
  • Recanati-Miller Transplantation Institute, The Icahn School of Medicine at Mount Sinai, New York, New York, USA.

ORCID profiles: Beatrice P Concepcion, Vasanthi Balaraman, Anju Yadav, Ankita Patel, Kenneth J Woodside, Krista L Lentine, M Lee Sanders, Oluwafisayo O Adebiyi, Sabiha M Hussain, Xingxing S Cheng, Ronald F Parsons

Cite

APA

Concepcion, B. P., Binari, L. A., Balaraman, V., Nishio-Lucar, A., Yadav, A., Patel, A., Woodside, K. J., Lentine, K. L., Sanders, M. L., Adebiyi, O. O., Hussain, S. M., Mehta, S., Viswanathan, V., Cheng, X. S., & Parsons, R. F. (2026). Hypothermic Machine Perfusion in Deceased Donor Kidney Transplantation: Provider and Transplant Center Practices and Perspectives. Clinical Transplantation. https://doi.org/10.1111/ctr.70637

Vancouver

Concepcion BP, Binari LA, Balaraman V, Nishio-Lucar A, Yadav A, Patel A, et al. Hypothermic Machine Perfusion in Deceased Donor Kidney Transplantation: Provider and Transplant Center Practices and Perspectives. Clinical Transplantation. 2026. doi:10.1111/ctr.70637

BibTeX
@article{Concepcion2026,
  author = {Concepcion, Beatrice P and Binari, Laura A and Balaraman, Vasanthi and Nishio-Lucar, Angie and Yadav, Anju and Patel, Ankita and Woodside, Kenneth J and Lentine, Krista L and Sanders, M Lee and Adebiyi, Oluwafisayo O and Hussain, Sabiha M and Mehta, Shikha and Viswanathan, Vignesh and Cheng, Xingxing S and Parsons, Ronald F},