Hypothermic Machine Perfusion in Deceased Donor Kidney Transplantation: Provider and Transplant Center Practices and Perspectives
Clinical Transplantation · 2026
DOI: 10.1111/ctr.70637 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Transplantation, 2026. Verfasst von Beatrice P Concepcion und 14 weiteren Autor:innen. Beteiligte Einrichtung: University of Chicago, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Kidney Transplantation, Organ Preservation, Perfusion, Tissue Donors. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Hypothermic machine perfusion (HMP), an organ preservation technique used in deceased donor kidney transplantation, improves early outcomes compared to traditional static cold storage while also providing a loosely validated organ viability assessment.
Methods
We designed a survey to better understand the practices, perceptions, and barriers to utilization of HMP. Surgeons, nephrologists, and coordinators were invited to participate in the survey via email.
Results
Respondents (90% transplant surgeons) from 88 transplant centers which utilize HMP (35% of active kidney transplant centers) participated, representing 63% of total transplant volume in 2024. Respondents strongly agreed that HMP is helpful in kidney selection (92%), reduces delayed graft function (90%), and allows for scheduling flexibility (91%). A majority (74%) answered that the Organ Procurement Organization (OPO exclusively pumps kidneys. The most cited barrier to HMP use was OPO refusal (58%). Thresholds for resistance and flow varied widely with over 2/3 of respondents citing a specified acceptable cut‐off. Most respondents answered “sometimes” (60%) or “yes” (20%) that they would decline a kidney if HMP could not be accomplished for a kidney they wished to be pumped. Perceived pitfalls were underutilization of kidneys due to incorrect or inaccurate perfusion parameters, logistical challenges and costs of pumping, inexperience and technical difficulties leading to organ or vasculature injury, and lack of standardization in practice.
Conclusions
HMP is used as a tool to assess organ viability and to overcome logistical hurdles by improving flexibility in operative timing. OPOs play a critical role in the ability to perform HMP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Chicago, Chicago, Illinois, USA.
- Vanderbilt University Medical Center, Nashville, Tennessee, USA.
- University of Tennessee Health Science Center, Memphis, Tennessee, USA.
- University of Virginia, Charlottesville, Virginia, USA.
- Johns Hopkins University, Baltimore, Maryland, USA.
- Recanati-Miller Transplantation Institute, The Icahn School of Medicine at Mount Sinai, New York, New York, USA.
ORCID-Profile: Beatrice P Concepcion, Vasanthi Balaraman, Anju Yadav, Ankita Patel, Kenneth J Woodside, Krista L Lentine, M Lee Sanders, Oluwafisayo O Adebiyi, Sabiha M Hussain, Xingxing S Cheng, Ronald F Parsons
Zitieren
APA
Concepcion, B. P., Binari, L. A., Balaraman, V., Nishio-Lucar, A., Yadav, A., Patel, A., Woodside, K. J., Lentine, K. L., Sanders, M. L., Adebiyi, O. O., Hussain, S. M., Mehta, S., Viswanathan, V., Cheng, X. S., & Parsons, R. F. (2026). Hypothermic Machine Perfusion in Deceased Donor Kidney Transplantation: Provider and Transplant Center Practices and Perspectives. Clinical Transplantation. https://doi.org/10.1111/ctr.70637
Vancouver
Concepcion BP, Binari LA, Balaraman V, Nishio-Lucar A, Yadav A, Patel A, et al. Hypothermic Machine Perfusion in Deceased Donor Kidney Transplantation: Provider and Transplant Center Practices and Perspectives. Clinical Transplantation. 2026. doi:10.1111/ctr.70637
BibTeX
@article{Concepcion2026,
author = {Concepcion, Beatrice P and Binari, Laura A and Balaraman, Vasanthi and Nishio-Lucar, Angie and Yadav, Anju and Patel, Ankita and Woodside, Kenneth J and Lentine, Krista L and Sanders, M Lee and Adebiyi, Oluwafisayo O and Hussain, Sabiha M and Mehta, Shikha and Viswanathan, Vignesh and Cheng, Xingxing S and Parsons, Ronald F},
title = {Hypothermic Machine Perfusion in Deceased Donor Kidney Transplantation: Provider and Transplant Center Practices and Perspectives},
journal = {Clinical Transplantation},
year = {2026},
doi = {10.1111/ctr.70637}
}
EUVIMED