Agreement between ultrasound protocols for the estimation of body fat percentage: Comparison to a four‐compartment model
Clinical Physiology and Functional Imaging · 2023
DOI: 10.1111/cpf.12835 ↗At a glance
Journal article in Clinical Physiology and Functional Imaging, 2023. Written by Katherine Sullivan and 4 co-authors. Institution: Exercise Physiology Laboratory, Department of Kinesiology, The University of Alabama, Tuscaloosa, Alabama, USA. Major MEDLINE topics: Adipose Tissue, Sports. Cited 5 times so far (Crossref); 55 references.
Abstract (original language)
The purpose of this study was to examine the agreement between body fat percentage (%Fat) estimates derived from a standardized ultrasound protocol (%Fat IASMS ), a commonly used skinfold (SKF)‐site‐based ultrasound protocol (%Fat JP ), and a criterion four‐compartment (4C) model (%Fat 4C ). For the ultrasound protocols, all measurement sites were marked, measured and analyzed by the same evaluator. Subcutaneous adipose tissue (SAT) thickness was measured manually at the region where the muscle fascia was parallel to the skin and the average value per measurement site was used to calculate body density and subsequently %Fat. A repeated‐measures analysis of variance with a priori planned contrasts was used to compare %Fat values between the 4C criterion and both ultrasound methods. Small nonsignificant mean differences were observed between %Fat IASMS (18.82 ± 14.21%Fat, effect size [ES] = 0.25, p = 0.178), %Fat JP (18.23 ± 13.32%Fat, ES = 0.32, p = 0.050) and the %Fat 4C criterion (21.70 ± 7.57%Fat); however, %Fat IASMS did not yield a smaller mean difference than the %Fat JP ( p = 0.287). Additionally, %Fat IASMS ( r = 0.90, p < 0.001, standard error of the estimate [SEE] = 3.29%) and %Fat JP ( r = 0.88, p < 0.001, SEE = 3.60%) were strongly correlated with the 4C criterion, however, %Fat IASMS did not yield better agreement than %Fat JP ( p = 0.257). Despite slightly underestimating %Fat, both ultrasound techniques demonstrated Good—Very Good agreement with the 4C criterion, with comparable mean differences, correlations, and SEE. The International Association of Sciences in Medicine and Sports (IASMS) standardized protocol using manual calculations of SAT was comparable to the SKF‐site‐based ultrasound protocol when compared to the 4C criterion. These results indicate that the IASMS (with manually measured SAT) and SKF‐site‐based ultrasound protocols may be of practical use to clinicians.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Exercise Physiology Laboratory, Department of Kinesiology, The University of Alabama, Tuscaloosa, Alabama, USA.
Cite
APA
Sullivan, K., Metoyer, C. J., Winchester, L. J., Esco, M. R., & Fedewa, M. V. (2023). Agreement between ultrasound protocols for the estimation of body fat percentage: Comparison to a four‐compartment model. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12835
Vancouver
Sullivan K, Metoyer CJ, Winchester LJ, Esco MR, Fedewa MV. Agreement between ultrasound protocols for the estimation of body fat percentage: Comparison to a four‐compartment model. Clinical Physiology and Functional Imaging. 2023. doi:10.1111/cpf.12835
BibTeX
@article{Sullivan2023,
author = {Sullivan, Katherine and Metoyer, Casey J and Winchester, Lee J and Esco, Michael R and Fedewa, Michael V},
title = {Agreement between ultrasound protocols for the estimation of body fat percentage: Comparison to a four‐compartment model},
journal = {Clinical Physiology and Functional Imaging},
year = {2023},
doi = {10.1111/cpf.12835}
}
EUVIMED