Acute exercise affects dual‐energy X‐ray absorptiometry body composition estimates but not standardised ultrasound measurements of subcutaneous adipose tissue
Clinical Physiology and Functional Imaging · 2023
DOI: 10.1111/cpf.12832 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical Physiology and Functional Imaging, 2023. Verfasst von Jun N Ong und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Human Sciences (Exercise and Sport Science), The University of Western Australia, Perth, Western Australia, Australia. Hauptthemen laut MEDLINE: Body Composition, Subcutaneous Fat. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Australian Commonwealth Government.
Abstract (Originalsprache)
Ultrasound has been demonstrated to be a highly accurate and reliable tool for measuring subcutaneous adipose tissue thickness and is robust against changes in hydration status or acute food or fluid intake. However, the effect of prior acute exercise is unexamined. This study examined the impact of an acute endurance exercise and resistance exercise session on standardised brightness‐mode ultrasound measurements of subcutaneous adipose tissue thickness compared to skinfolds and dual‐energy X‐ray absorptiometry body composition estimates. In a randomised cross‐over design, 30 active adults (24.2 ± 4.9 years) undertook physique assessment via standardised brightness‐mode ultrasound, skinfolds and dual‐energy X‐ray absorptiometry before, immediately and 45 min after an acute endurance or resistance exercise session. The mean sum of eight subcutaneous adipose tissue thickness measured via standardised brightness‐mode ultrasound increased (0.6 mm, p = 0.04) immediately postendurance exercise but was not meaningful when evaluated against the technical error of measurement of the investigator. A significant ( p = 0.01) but not meaningful decrease in the sum of eight skinfolds occurred immediately (−1.1 ± 0.4 mm) and 45 min (−1.3 ± 0.4 mm) postresistance exercise. Comparatively, endurance exercise elicited a meaningful decrease of total mass (460 ± 30 g) and trunk lean mass (680 ± 90 g) dual‐energy X‐ray absorptiometry estimates. Findings from this study indicate standardised client presentation may be unnecessary when employing either standardised brightness‐mode ultrasound or skinfolds for body composition assessment unlike dual‐energy X‐ray absorptiometry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Human Sciences (Exercise and Sport Science), The University of Western Australia, Perth, Western Australia, Australia.
- School of Allied Health, Curtin University, Perth, Western Australia, Australia.
- Centre for Applied Statistics, The University of Western Australia, Perth, Western Australia, Australia.
Förderung
- Australian Commonwealth Government
Zitieren
APA
Ong, J. N., Ducker, K. J., Furzer, B. J., Dymock, M., & Landers, G. J. (2023). Acute exercise affects dual‐energy X‐ray absorptiometry body composition estimates but not standardised ultrasound measurements of subcutaneous adipose tissue. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12832
Vancouver
Ong JN, Ducker KJ, Furzer BJ, Dymock M, Landers GJ. Acute exercise affects dual‐energy X‐ray absorptiometry body composition estimates but not standardised ultrasound measurements of subcutaneous adipose tissue. Clinical Physiology and Functional Imaging. 2023. doi:10.1111/cpf.12832
BibTeX
@article{Ong2023,
author = {Ong, Jun N and Ducker, Kagan J and Furzer, Bonnie J and Dymock, Michael and Landers, Grant J},
title = {Acute exercise affects dual‐energy X‐ray absorptiometry body composition estimates but not standardised ultrasound measurements of subcutaneous adipose tissue},
journal = {Clinical Physiology and Functional Imaging},
year = {2023},
doi = {10.1111/cpf.12832}
}
EUVIMED