EUVIMEDObjevte EUVIMED
VergleichsstudieOpen access · CC BY-NC 4.0

Less efficient skin penetration of the metal allergen Pd 2+ compared to Ni 2+ and Co 2+ from patch test preparations

Konstantin Simon iD, Philipp Reichardt iD, Andreas Luch, Alexander Roloff iD, Katherina Siewert iD, Franziska Riedel iD

Contact Dermatitis · 2024

DOI: 10.1111/cod.14569 ↗

At a glance

Vergleichsstudie in Contact Dermatitis, 2024. Written by Konstantin Simon and 5 co-authors. Institution: Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany. Major MEDLINE topics: Cobalt, Nickel, Palladium, Patch Tests. Cited 4 times so far (Crossref); 62 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: BfR-Internal Grants SFP, Deutsche Forschungsgemeinschaft.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Contrary to Ni 2+ ‐ and Co 2+ ‐induced allergic contact dermatitis (ACD), reactions against Pd 2+ are rare. However, Pd 2+ activates a larger T cell fraction in vitro , suggesting an inefficient skin penetration.

Objectives

This study compares Ni 2+ , Co 2+ and Pd 2+ skin penetration from commonly used diagnostic patch test preparations (PTPs) and aqueous metal salt solutions.

Methods

Using Franz diffusion cell assays, we applied the metals in PTPs (5% NiSO 4 , 1% CoCl 2 , 2% PdCl 2 and 3% Na 2 PdCl 4 ) and in solution to pigskin for 48 h, thereby mirroring the time frame of a patch test. The different compartments were analysed individually by inductively coupled plasma mass spectrometry.

Results

Metal ions were mainly retained in the upper stratum corneum layers. After application of PTPs, concentrations in the viable skin were lower for Pd 2+ (1 and 7 μM) compared to Ni 2+ and Co 2+ (54 and 17 μM).

Conclusions

Ni 2+ and Co 2+ penetrated the skin more efficiently than Pd 2+ and thus may sensitize and elicit ACD more easily. This was observed for ions applied in petrolatum and aqueous solutions. We hypothesize that the differently charged metal complexes are responsible for the varying skin penetration behaviours.

Subjects

MeSH terms (MEDLINE)

CobaltNickelPalladiumPatch TestsDermatitis, Allergic ContactAllergensSkin AbsorptionAnimalsSwineSkin

Author keywords

Franz diffusion cell assayNi, Co, PdT cell activationmetal allergypatch test preparationskin penetration

Substances

CobaltNickelPalladiumAllergenspalladium chloridecobaltous chloride

Authors and institutions

  • Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany.
  • Department of Biology, Chemistry, Pharmacy, Institute of Pharmacy, Freie Universität Berlin, Berlin, Germany.

ORCID profiles: Konstantin Simon, Philipp Reichardt, Alexander Roloff, Katherina Siewert, Franziska Riedel

Funding

  • BfR-Internal Grants SFP
  • Deutsche Forschungsgemeinschaft

Cite

APA

Simon, K., Reichardt, P., Luch, A., Roloff, A., Siewert, K., & Riedel, F. (2024). Less efficient skin penetration of the metal allergen Pd 2+ compared to Ni 2+ and Co 2+ from patch test preparations. Contact Dermatitis. https://doi.org/10.1111/cod.14569

Vancouver

Simon K, Reichardt P, Luch A, Roloff A, Siewert K, Riedel F. Less efficient skin penetration of the metal allergen Pd 2+ compared to Ni 2+ and Co 2+ from patch test preparations. Contact Dermatitis. 2024. doi:10.1111/cod.14569

BibTeX
@article{Simon2024,
  author = {Simon, Konstantin and Reichardt, Philipp and Luch, Andreas and Roloff, Alexander and Siewert, Katherina and Riedel, Franziska},
  title = {Less efficient skin penetration of the metal allergen Pd 2+ compared to Ni 2+ and Co 2+ from patch test preparations},
  journal = {Contact Dermatitis},
  year = {2024},
  doi = {10.1111/cod.14569}
}
Start for free →