Interference of the positioning of nickel, chromium and cobalt in the results of patch tests
Anais Brasileiros de Dermatologia · 2025
DOI: 10.1016/j.abd.2024.03.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Anais Brasileiros de Dermatologia, 2025. Verfasst von Ida Duarte und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Faculty of Medical Sciences, Santa Casa de São Paulo, São Paulo, SP, Brazil. Electronic address: idaduarte@terra.com.br. Hauptthemen laut MEDLINE: Patch Tests, Nickel, Cobalt, Chromium. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State of Sao Paulo Research Foundation.
Abstract (Originalsprache)
Background
The positioning of substances, which are co-sensitizers and/or with a tendency to cross-react, is not considered in the technique when applying patch tests (PT).
Objective
To investigate the interference of the positioning of nickel (Ni), chromium (Cr) and cobalt (Co) in patch tests (PT) results, when applied close or distant from each other.
Methods
PT were performed in patients suspected of allergic contact dermatitis (ACD), using the standard battery (SB), with substances showing a tendency towards cross-react and cosensitizers applied far apart, and an additional battery (AB) with the metals placed close to each other. For tabulation purposes, only the 96-h reading was considered.
Results
Of the 86 tested patients, 33 (38%) had negative testing for metals and 53 (62%) had one or more positive (+) tests for Ni, Cr and/or Co. Concordant results in both tests (SB/ AB) occurred in 18/53 (34%) and 35/53 (66%) had discordant results. Regarding the SB, of the 159 tests with metals (53 patients, three metals), 57 tests were (+) and 102 (-). In the AB, 87 tests were (+) and 72 (-), a statistically significant difference (p < 0.05). Of the 57 (+) tests in the SB, 35 were for Ni, 18 for Co and four for Cr. In AB the number of (+) tests was 87, with 45 (+) tests for Ni, 35 for Co and seven for Cr. The difference in the number of positive tests between the two batteries was statistically significant for Co and Ni. Study limitations: The number of cases.
Conclusion
The results showed that the positioning of the metals interferes with the PT results and should be considered as part of the PT application technique.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medicine, Faculty of Medical Sciences, Santa Casa de São Paulo, São Paulo, SP, Brazil. Electronic address: idaduarte@terra.com.br.
- Department of Medicine, Dermatology Clinic, Santa Casa de São Paulo, São Paulo, SP, Brazil.
- Department of Medicine, Faculty of Medical Sciences, Santa Casa de São Paulo, São Paulo, SP, Brazil.
Förderung
- State of Sao Paulo Research Foundation
Zitieren
APA
Duarte, I., Lazzarini, R., Haffner, M., & Silva, J. P. (2025). Interference of the positioning of nickel, chromium and cobalt in the results of patch tests. Anais Brasileiros de Dermatologia. https://doi.org/10.1016/j.abd.2024.03.016
Vancouver
Duarte I, Lazzarini R, Haffner M, Silva JP. Interference of the positioning of nickel, chromium and cobalt in the results of patch tests. Anais Brasileiros de Dermatologia. 2025. doi:10.1016/j.abd.2024.03.016
BibTeX
@article{Duarte2025,
author = {Duarte, Ida and Lazzarini, Rosana and Haffner, Mariana and Silva, Julia P},
title = {Interference of the positioning of nickel, chromium and cobalt in the results of patch tests},
journal = {Anais Brasileiros de Dermatologia},
year = {2025},
doi = {10.1016/j.abd.2024.03.016}
}
EUVIMED