A Randomised Controlled Trial Comparing a One‐Piece Zirconia Tissue‐Level Implant and Two‐Piece Titanium Bone‐Level Implant for Maxillary Single Tooth Replacement—3 year Results
Clinical Oral Implants Research · 2026
DOI: 10.1111/clr.70148 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, 2026. Verfasst von J H W de Beus und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry Orthodontics, Section of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Groningen, the …. Hauptthemen laut MEDLINE: Zirconium, Titanium, Dental Implants, Single-Tooth, Dental Implantation, Endosseous. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: ITI Research Grand.
Abstract (Originalsprache)
Objectives
This RCT evaluated and compared the clinical performance of zirconia and titanium dental implants placed in the maxillary premolar region. Outcomes were assessed 3 years after prosthetic loading and included marginal bone level (MBL) changes, clinical parameters, aesthetic outcomes, and patient related outcome measures (PROMs). Materials and Methods Fifty patients were randomly allocated to receive either a zirconia one‐piece (ZrO 2 , n = 25) implant or a titanium bone‐level (Ti, n = 25) implant, restored with a lithium disilicate crown 3 months after implant placement. Primary outcome was change in MBL. Secondary outcomes included implant survival, peri‐implant tissue health, technical complications, aesthetic outcomes, and PROMs. Examinations were performed 3 years after crown placement.
Results
After 3 years, mean MBL change was −0.02 mm (SD = 0.78) for ZrO 2 and −0.04 mm (SD = 0.36) for Ti; no statistically significant difference was found ( p = 0.635). One ZrO 2 implant failed to osseointegrate. Clinical parameters were favourable for both implant types, although slightly higher bleeding scores were observed for ZrO 2 . Differences in aesthetic outcomes and PROMs were found, favoring the ZrO 2 implant group. None of these differences reached statistical significance. Conclusion and Clinical Implications After 3 years of function, the ZrO 2 and Ti implant as applied in this study showed comparable MBL changes. Survival, clinical and aesthetic parameters, and PROMs were generally favourable and largely comparable for both groups. These short‐term findings indicate that both implant types represent a viable option for clinical use in this application. Trial Registration CCMO registration: NL58957.042.16
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Dentistry Orthodontics, Section of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
- Department of Oral Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
- Department of Oral Maxillofacial Surgery, Prosthodontics and Special Dental Care, St. Antonius Hospital, Nieuwegein, the Netherlands.
- Department of Epidemiology, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
ORCID-Profile: J H W de Beus, J W A Slot, H J A Meijer, G M Raghoebar, U Schepke
Förderung
- ITI Research Grand
Zitieren
APA
de Beus, J. H. W., Cune, M. S., Muijselaar, L., Slot, J. W. A., Jensen-Louwerse, C., la Bastide-van Gemert, S., Meijer, H. J. A., Raghoebar, G. M., & Schepke, U. (2026). A Randomised Controlled Trial Comparing a One‐Piece Zirconia Tissue‐Level Implant and Two‐Piece Titanium Bone‐Level Implant for Maxillary Single Tooth Replacement—3 year Results. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70148
Vancouver
de Beus JHW, Cune MS, Muijselaar L, Slot JWA, Jensen-Louwerse C, la Bastide-van Gemert S, et al. A Randomised Controlled Trial Comparing a One‐Piece Zirconia Tissue‐Level Implant and Two‐Piece Titanium Bone‐Level Implant for Maxillary Single Tooth Replacement—3 year Results. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70148
BibTeX
@article{deBeus2026,
author = {de Beus, J H W and Cune, M S and Muijselaar, L and Slot, J W A and Jensen-Louwerse, C and la Bastide-van Gemert, S and Meijer, H J A and Raghoebar, G M and Schepke, U},
title = {A Randomised Controlled Trial Comparing a One‐Piece Zirconia Tissue‐Level Implant and Two‐Piece Titanium Bone‐Level Implant for Maxillary Single Tooth Replacement—3 year Results},
journal = {Clinical Oral Implants Research},
year = {2026},
doi = {10.1111/clr.70148}
}
EUVIMED