Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2026. Verfasst von Simon Systermans und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Maxillofacial Surgery, CHU Liège, Liège, Belgium. Hauptthemen laut MEDLINE: Osseointegration, Printing, Three-Dimensional, Durapatite, Dental Implants. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Gouvernement Wallon, European Regional Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the use and osseointegration of dental implants in combination with 3D‐printed hydroxyapatite (3DHA) blocks featuring gyroid porosity for large mandibular bone augmentation.

Methods

Mandibular lateral bone augmentation with gyroid‐3DHA blocks was performed bilaterally on four female Göttingen minipigs. After 8 or 12 weeks of healing, a dental implant was placed into each 3DHA block. Following an additional 12‐week healing period, the augmented sites (including 3DHA blocks and dental implants) were harvested for histological and histomorphometric analysis, assessing new bone formation, 3DHA integration, total bone gain, and bone‐to‐implant contact (BIC).

Results

Gyroid‐3DHA blocks were easily fixated with screws. Dental implants were placed through the 3DHA blocks with a standard drilling procedure, and good primary stability was achieved. 3DHA blocks demonstrated good osseointegration with 39.17% of new bone and a significant bone gain of 4.73 mm on average. Dental implants showed comparable BIC within the 3DHA and into the native bone (42.79% vs. 34.17%). No significant difference was found between the healing periods.

Conclusion

This is the first study to evaluate a 3D‐printed bone substitute in combination with a dental implant in an animal study. Gyroid‐3DHA blocks and dental implants demonstrated good osseointegration, and the bone augmentation was significant, making it a promising material for large and complex alveolar ridge augmentations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsseointegrationPrinting, Three-DimensionalDurapatiteDental ImplantsMandibleDental Implantation, EndosseousAlveolar Ridge AugmentationAnimalsSwineSwine, MiniatureFemale

Stichwörter der Autor:innen

3D printingalveolar ridge augmentationdental implantsguided bone regenerationoral surgeryosseointegrationscaffoldtissue engineering

Substanzen

DurapatiteDental Implants

Autor:innen und Institutionen

  • Department of Plastic and Maxillofacial Surgery, CHU Liège, Liège, Belgium.
  • Faculty of Medicine, University of Liège, Liège, Belgium.
  • Department of Plastic, Esthetic and Reconstructive Surgery, CHR Citadelle Liège, Liège, Belgium.
  • Faculty of Medicine, University of Namur, Namur, Belgium.
  • Cerhum SA, Liège, Belgium.
  • Department of Oral and Maxillofacial Surgery, ZOL Genk, Genk, Belgium.

ORCID-Profile: Elisabeth Cobraiville

Förderung

  • Gouvernement Wallon
  • European Regional Development Fund

Zitieren

APA

Systermans, S., Ronsmans, C., Nolens, G., Meyns, J., Gilon, Y., & Cobraiville, E. (2026). Dental Implant Osseointegration Following Mandibular Augmentation Using 3D Printed Hydroxyapatite Blocks. An Experimental In Vivo Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70056

Vancouver

Systermans S, Ronsmans C, Nolens G, Meyns J, Gilon Y, Cobraiville E. Dental Implant Osseointegration Following Mandibular Augmentation Using 3D Printed Hydroxyapatite Blocks. An Experimental In Vivo Study. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70056

BibTeX
@article{Systermans2026,
  author = {Systermans, Simon and Ronsmans, Christophe and Nolens, Grégory and Meyns, Joeri and Gilon, Yves and Cobraiville, Elisabeth},
  title = {Dental Implant Osseointegration Following Mandibular Augmentation Using 3D Printed Hydroxyapatite Blocks. An Experimental In Vivo Study},
  journal = {Clinical Oral Implants Research},
  year = {2026},
  doi = {10.1111/clr.70056}
}
Kostenlos starten →