Influence of Horizontal Intraoral Scan Bodies on the Trueness of Digital Impressions for Complete‐Arch Prostheses on Four Implants: An In Vitro Evaluation
Clinical Oral Implants Research · 2025-10 · 36 (10) · 1287-1295
DOI: 10.1111/clr.70001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 18.07.2025. Verfasst von Andrea Laureti und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Implants, Computer-Aided Design, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To assess the impact of horizontal intraoral scan bodies (H‐ISBs) on the trueness of complete‐arch digital impressions compared to vertical ISBs (V‐ISBs). To evaluate trueness among four intraoral scanners (IOS) and inter‐operator variability across different ISB × IOS combinations. Materials and Methods Digital impressions were made from a dental cast with four multi‐unit analogs using four H‐ISBs: H‐NB, H‐NS, H‐M6, H‐SF, and a V‐ISB (V‐EA) as a comparison. Two operators performed 10 scans per ISB with four IOS devices (i5D, PS, T3, T4), generating 400 impressions. Reference scans were obtained with a desktop scanner, and trueness was analyzed using root‐mean‐square (RMS) error calculations ( α = 0.05).
Results
H‐NS and H‐SF exhibited the highest trueness across IOSs, whereas H‐NB and H‐M6 showed lower trueness. V‐EA outperformed H‐NB and H‐M6 but not H‐NS and H‐SF. Significant IOS‐ISB interaction effects ( p < 0.01) indicated H‐SF as the most accurate, especially with PS. T4 and i5D displayed greater variability, particularly with H‐NB. V‐ISBs exhibited higher inter‐operator variability compared to H‐ISBs.
Conclusions
H‐ISBs did not perform better than V‐ISBs in all scenarios. The interactions among ISB design, IOS type, and operator significantly affect the digital impression trueness. The discrepancies measured among the systems remain well below the currently accepted threshold for clinically relevant misfit, supporting the suitability of the horizontal configuration for complete‐arch impressions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy.
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
- Faculty of Dental Medicine, The Catholic University of Portugal (UCP), Viseu, Portugal.
- Center for Interdisciplinary Research in Health, The Catholic University of Portugal (UCP), Viseu, Portugal.
- Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, Rome, Italy.
- Department of Restorative Sciences, The Dental College of Georgia at Augusta University, Augusta, Georgia, USA.
ORCID-Profile: João Pitta, Irena Sailer, Luís Azevedo
Zitieren
APA
Laureti, A., Marques, T., Pitta, J., Fehmer, V., Sailer, I., Pozzi, A., & Azevedo, L. (2025). Influence of Horizontal Intraoral Scan Bodies on the Trueness of Digital Impressions for Complete‐Arch Prostheses on Four Implants: An In Vitro Evaluation. Clinical Oral Implants Research, 36(10), 1287-1295. https://doi.org/10.1111/clr.70001
Vancouver
Laureti A, Marques T, Pitta J, Fehmer V, Sailer I, Pozzi A, et al. Influence of Horizontal Intraoral Scan Bodies on the Trueness of Digital Impressions for Complete‐Arch Prostheses on Four Implants: An In Vitro Evaluation. Clinical Oral Implants Research. 2025;36(10):1287-1295. doi:10.1111/clr.70001
BibTeX
@article{Laureti2025,
author = {Laureti, Andrea and Marques, Tiago and Pitta, João and Fehmer, Vincent and Sailer, Irena and Pozzi, Alessandro and Azevedo, Luís},
title = {Influence of Horizontal Intraoral Scan Bodies on the Trueness of Digital Impressions for Complete‐Arch Prostheses on Four Implants: An In Vitro Evaluation},
journal = {Clinical Oral Implants Research},
year = {2025},
volume = {36},
number = {10},
pages = {1287--1295},
doi = {10.1111/clr.70001}
}
EUVIMED