Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete‐Arch Implant Impression: An In Vitro Study
Clinical Oral Implants Research · 2025-01 · 36 (1) · 17-27
DOI: 10.1111/clr.14353 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 04.09.2024. Verfasst von Xiao-Jiao Fu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong Univ…. Hauptthemen laut MEDLINE: Dental Impression Technique. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, the Cross-disciplinary Research Fund of Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai Young Talent for Health.
Abstract (Originalsprache)
Objectives
This study aimed to compare the accuracy of digital complete‐arch implant impressions with prefabricated aids using three intraoral scanners (IOSs) and explore the correlation between virtual deviation measurement and physical framework misfit. Materials and Methods Four edentulous maxillary master models with four and six parallel and angular implants were fabricated and scanned by a laboratory scanner as reference scans. Ten scans of each master model were acquired using three IOSs (IOS‐T, IOS‐M, and IOS‐A) with and without prefabricated aids. Trueness and precision of root mean square (RMS) errors were measured. Ten aluminum alloy frameworks were fabricated, and the misfit was measured with a micro‐computed tomography scan with one screw tightened.
Results
Trueness and precision showed significant improvement when prefabricated aids were used for all three IOSs ( p < 0.010). Median (interquartile range) RMS errors of trueness reduced from 67.5 (30.4) to 61.8 (30.3) μm, from 100.6 (35.4) to 45.9 (15.1) μm, and from 52.7 (33.2) to 41.1 (22.5) μm for scanner IOS‐T, IOS‐M, and IOS‐A, respectively ( p < 0.010). The precision of IOS‐A and IOS‐M was significantly better than IOS‐T when using prefabricated aid ( p < 0.001). RMS errors and the maximum marginal misfit of the framework were significantly correlated ( p < 0.001, R 2 = 0.845).
Conclusions
With the prefabricated aids, the accuracy of IOSs enhanced significantly in digital complete‐arch implant impressions. Three IOSs showed different levels of improvement in accuracy. Virtual RMS errors
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong…
- Division of Periodontology and Implant Dentistry, The Faulty of Dentistry, The University of Hong Kong, Hong Kong, China.
ORCID-Profile: Xiao-Jiao Fu, Hong-Chang Lai
Förderung
- Fundamental Research Funds for the Central Universities
- the Cross-disciplinary Research Fund of Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine
- Shanghai Young Talent for Health
Zitieren
APA
Fu, X. J., Liu, M., Shi, J. Y., Deng, K., Lai, H. C., Gu, W., & Zhang, X. M. (2025). Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete‐Arch Implant Impression: An In Vitro Study. Clinical Oral Implants Research, 36(1), 17-27. https://doi.org/10.1111/clr.14353
Vancouver
Fu XJ, Liu M, Shi JY, Deng K, Lai HC, Gu W, et al. Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete‐Arch Implant Impression: An In Vitro Study. Clinical Oral Implants Research. 2025;36(1):17-27. doi:10.1111/clr.14353
BibTeX
@article{Fu2025,
author = {Fu, Xiao-Jiao and Liu, Min and Shi, Jun-Yu and Deng, Ke and Lai, Hong-Chang and Gu, Wen and Zhang, Xiao-Meng},
title = {Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete‐Arch Implant Impression: An In Vitro Study},
journal = {Clinical Oral Implants Research},
year = {2025},
volume = {36},
number = {1},
pages = {17--27},
doi = {10.1111/clr.14353}
}
EUVIMED