Accuracy of a complete arch noncalibrated splinting implant scanning technique with a palatal orientation recorded by using different intraoral scanners
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2025.02.020 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Dental Arch, Dental Implants, Dental Prosthesis Design. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The accuracy of noncalibrated splinting implant scanning techniques that include horizontal implant scan bodies (ISBs) positioned connecting the implants by following the shape of the dental arch have previously been analyzed. A novel horizontal ISB connected in the center of the arch has been introduced; however, the accuracy of this noncalibrated splinting implant scanning technique with a palatal orientation is unknown. PURPOSE: The purpose of this in vitro study was to compare the accuracy of a nonsplinting and noncalibrated splinting implant scanning technique recorded using 5 intraoral scanners (IOSs). MATERIAL AND METHODS: A laboratory scan (reference scan) of an edentulous stone cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was acquired (T710). Five groups were created based on the IOS tested: TRIOS 5, Primescan, i700, Aoralscan3, and iTero Element 5D. Two subgroups were defined based on the implant scanning technique used to record complete arch implant scans: a nonsplinted (NS-ISB subgroup) or noncalibrated splinting (NCS-IOC group) implant scanning technique (n=10). In the NS-ISB subgroup, an ISB (TrueScan Body) was positioned on each implant abutment, and complete arch implant scans were recorded and exported in standard tessellation language (STL) format. In the NCS-IOC subgroup, a horizontal ISB (IOConnect) was positioned on each implant abutment connecting them in the center of the palate. Implant scans were recorded, capturing only the section of the horizontal ISBs located in the center of the arch. Then, the scans were processed by a specific program (TruSuite), and the STL of the scans were exported. A program (Geomagic) was used to perform linear and angular measurements among the ISBs in the control scan and each specimen. The measurements obtained in the control scan were used as a reference to measure the scanning distortion of each specimen. The 2-way ANOVA Welch and pairwise multiple comparison Tukey tests were used to analyze trueness (α=.05). The Levene and pairwise multiple comparison Wilcoxon rank tests were used to analyze precision (α=.05). RESULTS: Linear trueness discrepancies were found among the groups (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director, Research and Digital Dentistry, Kois Cent…
- Collaborating Professor of Postgraduate Specialist in Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spa…
- Assistant Professor Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
- Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle,…
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.
Zitieren
APA
Revilla-León, M., Cascos, R., Barmak, A. B., Kois, J. C., & Gómez-Polo, M. (2026). Accuracy of a complete arch noncalibrated splinting implant scanning technique with a palatal orientation recorded by using different intraoral scanners. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.02.020
Vancouver
Revilla-León M, Cascos R, Barmak AB, Kois JC, Gómez-Polo M. Accuracy of a complete arch noncalibrated splinting implant scanning technique with a palatal orientation recorded by using different intraoral scanners. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2025.02.020
BibTeX
@article{RevillaLen2026,
author = {Revilla-León, Marta and Cascos, Rocio and Barmak, Abdul B and Kois, John C and Gómez-Polo, Miguel},
title = {Accuracy of a complete arch noncalibrated splinting implant scanning technique with a palatal orientation recorded by using different intraoral scanners},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2025.02.020}
}
EUVIMED