Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, 2025. Verfasst von Jiaxian Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Lab…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Dental Implantation, Endosseous, Dental Implants, Single-Tooth. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: THETA, Jianjia, Hangzhou, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the implant accuracy, safety, and efficiency between robotic‐assisted and freehand dental implant placement with a half‐year follow‐up.

Methods

Patients requiring single‐tooth implant restorations were recruited and randomized into two groups: robotic‐assisted surgery and freehand implant surgery. The accuracy of implant positioning was compared by assessing immediate postoperative CBCT scans against preoperative planning software. Intraoperative and postoperative complications were recorded, and data were analyzed using an intention‐to‐treat approach. The time required for implant placement in each group was documented. A 6‐month follow‐up measured the implant survival rates.

Results

The study included 24 patients (median age 36, 18 female). In the robotic‐assisted surgery group, the average platform global deviation, apex global deviation, and angular deviation were 0.70 ± 0.11 mm, 0.70 ± 0.12 mm, and 1.09° ± 0.67°, respectively. In the freehand implant surgery group, these measures were 1.24 ± 0.59 mm, 2.13 ± 1.26 mm, and 7.43° ± 6.12°, respectively, with statistically significant differences. Regarding the duration of surgery, the robotic‐assisted surgery group required 18.8 ± 4.89 min. Intraoperative and postoperative complications were similar across both groups, and the implant survival rate was 100% in both groups at the 6‐month follow‐up.

Conclusions

This study found that robot‐assisted implant placement offers higher accuracy in implant positioning compared to freehand placement, while requiring longer operation times. Future developments should focus on simplifying the registration and design of robot systems to enhance efficiency and facilitate their broader clinical adoption.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresDental Implantation, EndosseousDental Implants, Single-ToothHumansFemaleMaleAdultFollow-Up StudiesMiddle AgedTreatment OutcomeCone-Beam Computed TomographyPostoperative Complications

Stichwörter der Autor:innen

dental implantdigital dentistrypositional accuracyrobot assisted surgerysurvival rate

Autor:innen und Institutionen

  • State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan Univer…
  • Department of Oral Implantology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
  • Oral Biomaterials and Application Technology Engineering Research Center of Hubei Province, Wuhan, China.

ORCID-Profile: Yufeng Zhang

Förderung

  • THETA, Jianjia, Hangzhou, China

Zitieren

APA

Chen, J., Wang, Y., Bai, Y., Chen, Y., Chen, Z., Yan, Q., & Zhang, Y. (2025). Accuracy, Safety, and Efficiency in Robotic‐Assisted vs. Freehand Dental Implant Surgery: A 6‐Month Follow‐Up Randomized Controlled Trial. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14413

Vancouver

Chen J, Wang Y, Bai Y, Chen Y, Chen Z, Yan Q, et al. Accuracy, Safety, and Efficiency in Robotic‐Assisted vs. Freehand Dental Implant Surgery: A 6‐Month Follow‐Up Randomized Controlled Trial. Clinical Oral Implants Research. 2025. doi:10.1111/clr.14413

BibTeX
@article{Chen2025,
  author = {Chen, Jiaxian and Wang, Yulan and Bai, Yi and Chen, Yan and Chen, Zhenqi and Yan, Qi and Zhang, Yufeng},
  title = {Accuracy, Safety, and Efficiency in Robotic‐Assisted vs. Freehand Dental Implant Surgery: A 6‐Month Follow‐Up Randomized Controlled Trial},
  journal = {Clinical Oral Implants Research},
  year = {2025},
  doi = {10.1111/clr.14413}
}
Kostenlos starten →