A 7.5‐year randomized controlled clinical study comparing cemented and screw‐retained one‐piece zirconia‐based implant‐supported single crowns
Clinical Oral Implants Research · 2024-12 · 35 (12) · 1669-1675
DOI: 10.1111/clr.14346 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 22.08.2024. Verfasst von Riccardo D Kraus und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Zirconium, Crowns, Dental Prosthesis, Implant-Supported, Dental Implants, Single-Tooth. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objectives
To compare marginal bone levels, biological, and technical outcomes of screw‐retained versus cemented all‐ceramic implant‐supported zirconia‐based single crowns after an observation period of 7.5 years.
Methods
Forty‐four single implants in the esthetic zone in 44 patients (22 females, 22 males) were randomly assigned to two types of restorations: SR (screw‐retained); veneered one‐piece zirconia abutment and CR (cement‐retained); veneered lithium disilicate crown intraorally cemented on a one‐piece zirconia abutment. Patients were recalled annually up to 7.5 years and survival rates, biological, and technical parameters assessed.
Results
A total of 31 patients attended the 7.5‐year follow‐up visit (17 SR group, 14 CR group). The survival rate on the restorative level was 77.5% (74.0% CR, 81.0% SR, p = .6399). Median marginal bone loss (MBL) values yielded −0.073 mm (−0.305; 0.238) in the CR and −0.215 mm (−0.500; 0.555) in the SR group (intergroup p = .6194). Mean bleeding on probing (BoP) values were significantly in favor of group SR with 20 ± 17% compared to 40 ± 22% in group CR ( p = .011). The overall biological complication rate amounted to 27.5% (42.1% CR, 14.3% SR, p = .0775), whereas the technical complication rate was 32.5% (42.1% CR, 23.8% SR, p = .314). In total, CR restorations showed significantly more complications (84.2% for CR, 38.1% for SR, p = .0041).
Conclusion
One‐piece zirconia‐based single crowns on two‐piece dental implants exhibited a high rate of technical and biological complications at 7.5 years of follow‐up. Cemented restorations revealed significant higher rates of bleeding on probing and total complications compared to screw‐retained restorations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.
ORCID-Profile: Riccardo D Kraus, Nadja Naenni, Marc Balmer, Ronald E Jung, Daniel S Thoma
Zitieren
APA
Kraus, R. D., Hjerppe, J., Naenni, N., Balmer, M., Jung, R. E., & Thoma, D. S. (2024). A 7.5‐year randomized controlled clinical study comparing cemented and screw‐retained one‐piece zirconia‐based implant‐supported single crowns. Clinical Oral Implants Research, 35(12), 1669-1675. https://doi.org/10.1111/clr.14346
Vancouver
Kraus RD, Hjerppe J, Naenni N, Balmer M, Jung RE, Thoma DS. A 7.5‐year randomized controlled clinical study comparing cemented and screw‐retained one‐piece zirconia‐based implant‐supported single crowns. Clinical Oral Implants Research. 2024;35(12):1669-1675. doi:10.1111/clr.14346
BibTeX
@article{Kraus2024,
author = {Kraus, Riccardo D and Hjerppe, Jenni and Naenni, Nadja and Balmer, Marc and Jung, Ronald E and Thoma, Daniel S},
title = {A 7.5‐year randomized controlled clinical study comparing cemented and screw‐retained one‐piece zirconia‐based implant‐supported single crowns},
journal = {Clinical Oral Implants Research},
year = {2024},
volume = {35},
number = {12},
pages = {1669--1675},
doi = {10.1111/clr.14346}
}
EUVIMED