EUVIMEDEUVIMED entdecken
Kontrollierte klinische StudieOpen Access · CC BY 4.0

Nano-superhydrophilic and bioactive surface in poor bone environment. Part 1: transition from primary to secondary stability. A controlled clinical trial

Luigi Canullo iD, Maria Menini, Paolo Pesce iD, Roberta Iacono iD, Anton Sculean iD, Massimo Del Fabbro

Clinical Oral Investigations · 2024

DOI: 10.1007/s00784-024-05747-7 ↗

Kurz gefasst

Kontrollierte klinische Studie in der Zeitschrift Clinical Oral Investigations, 2024. Verfasst von Luigi Canullo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy. luigicanullo@yahoo.com. Hauptthemen laut MEDLINE: Surface Properties, Bone Density, Torque, Dental Implants. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Bern.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Bioactive surfaces were designed to increase the interaction between the surface and the cells. This may speed up the biological stability and loading protocols. Materials and methods 36 patients with D3-D4 bone density were recruited and allocated into two groups. 30 bioactive (test group) and 30 traditional (control group) surfaced implants were placed. Insertion torque value (Ncm), insertion torque curve integral (cumulative torque, Ncm), torque density (Ncm/sec), implant stability quotient (ISQ) measured at three timepoints (baseline (T0), 30 (T30) and 45 (T45) days after surgery), and marginal bone loss (MBL) at 6 months of loading were assessed.

Results

The mean ISQ and standard deviation at T0, T30, T45 were respectively 74.57 ± 7.85, 74.78 ± 7.31, 74.97 ± 6.34 in test group, and 77.12 ± 5.83, 73.33 ± 6.13, 73.44 ± 7.89 in control group, respectively. Data analysis showed significant differences between groups in ΔISQ at T0-T30 ( p = 0.005) and T30-T45 ( p = 0.012). Control group showed a significant decrease in ISQ at T30 ( p = 0.01) and T45 ( p = 0.03) compared to baseline, while no significant change was observed in test group. Due to the stability of the ISQ value ≥ 70, 26 test group and 23 control group implants were functionally loaded after 45 days. Conversely, due to the ISQ < 70 at T45, four test group implants and one control group implant were loaded after 90 days, and 6 control group implants were loaded after 180 days. Neither insertion torque nor ISQ at baseline were correlated with bone density (in Hounsfield units). There was no significant correlation between cumulative torque and ISQ at baseline. There was a significant positive slope in the correlation between torque density and ISQ at baseline, more accentuated in D3 than D4. This correlation remained significant for the test group in D3 bone at day 30 and 45 ( p < 0.01 in both time frames), but not in D4 bone, and it was not significant in CG.

Conclusions

The bioactive surface showed better behavior in terms of implant stability in D3-D4 bone quality in the early stages of bone healing. Clinical relevance This study demonstrated that the transition from primary to secondary stability is improved using bioactive surface, especially in cases of poor bone environment (D3/D4 bone).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surface PropertiesBone DensityTorqueDental ImplantsDental Implantation, EndosseousHumansMaleFemaleMiddle AgedDental Prosthesis DesignAdultTreatment OutcomeOsseointegration

Stichwörter der Autor:innen

Bioactive surfaceClinical trialImplant stabilityImplant surfaceInsertion torque valueOsseointegration

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy. luigicanullo@yahoo.com.
  • Department of Periodontology, University of Bern, Bern, Switzerland. luigicanullo@yahoo.com.
  • Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy.
  • Department of Oral and Maxillo-facial Sciences, "Sapienza" University of Rome, Via Caserta 6, Rome, 00161, Italy.
  • Department of Periodontology, University of Bern, Bern, Switzerland.
  • Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.

ORCID-Profile: Luigi Canullo, Paolo Pesce, Roberta Iacono, Anton Sculean

Förderung

  • University of Bern

Zitieren

APA

Canullo, L., Menini, M., Pesce, P., Iacono, R., Sculean, A., & Del Fabbro, M. (2024). Nano-superhydrophilic and bioactive surface in poor bone environment. Part 1: transition from primary to secondary stability. A controlled clinical trial. Clinical Oral Investigations. https://doi.org/10.1007/s00784-024-05747-7

Vancouver

Canullo L, Menini M, Pesce P, Iacono R, Sculean A, Del Fabbro M. Nano-superhydrophilic and bioactive surface in poor bone environment. Part 1: transition from primary to secondary stability. A controlled clinical trial. Clinical Oral Investigations. 2024. doi:10.1007/s00784-024-05747-7

BibTeX
@article{Canullo2024,
  author = {Canullo, Luigi and Menini, Maria and Pesce, Paolo and Iacono, Roberta and Sculean, Anton and Del Fabbro, Massimo},
  title = {Nano-superhydrophilic and bioactive surface in poor bone environment. Part 1: transition from primary to secondary stability. A controlled clinical trial},
  journal = {Clinical Oral Investigations},
  year = {2024},
  doi = {10.1007/s00784-024-05747-7}
}
Kostenlos starten →