EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Clinical and Radiographic Outcomes of Customized Titanium Mesh vs. Screw Tent‐Pole Grafting: A Retrospective Study

G Wurtz, F Bagnasco, M Menini iD, P Pesce iD, D Baldi, N De Angelis iD

Clinical Implant Dentistry and Related Research · 2026-04 · 28 (2)

DOI: 10.1111/cid.70139 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 20.03.2026. Verfasst von G Wurtz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Sciences and Integrated Diagnostics, University of Genoa DISC, Genova, Italy. Hauptthemen laut MEDLINE: Titanium, Alveolar Ridge Augmentation, Surgical Mesh, Bone Screws. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Guided bone regeneration (GBR) is a predictable approach for managing severe alveolar ridge deficiencies prior to implant placement. Resorbable collagen membranes supported by tenting screws are widely used, although space maintenance in non‐contained defects may be challenging. Customized CAD/CAM titanium meshes have been introduced to enhance graft stability and surgical workflow, but comparative clinical evidence remains limited.

Objective

To compare clinical, radiographic, procedural, and peri‐implant outcomes of customized CAD/CAM titanium meshes versus resorbable collagen membranes supported by tenting screws for horizontal and/or vertical alveolar ridge augmentation. Materials and Methods This retrospective study included 40 patients with severe alveolar ridge defects, allocated to two groups ( n = 20 each). Both groups received particulate bone grafts stabilized either with tenting screws and a resorbable collagen membrane or with a patient‐specific CAD/CAM titanium mesh. Cone‐beam computed tomography (CBCT) scans at baseline and 6 months were used to assess vertical and horizontal bone gain. Intraoperative time, complications, pseudo‐periosteum formation, implant survival, and peri‐implant marginal bone levels at prosthetic loading and at 5‐year follow‐up were recorded.

Results

At 6 months, mean bone height reached 8.7–8.93 mm in the maxilla and 9.25–9.35 mm in the mandible, while mean ridge width ranged from 4.7 to 5.3 mm, with no significant intergroup differences ( p > 0.05). Mean peri‐implant marginal bone loss was limited and remained stable from prosthetic loading to the 5‐year follow‐up in both groups. Mean operative time was significantly shorter in the customized mesh group, 72.7 min (range: 60–85) for the Tent‐pole group and 62.4 min (range: 60–65) for the Ti‐mesh group. All 60 implants placed in 40 augmented sites survived, with no implant failures and no need for additional grafting procedures.

Conclusions

Both GBR techniques provided comparable bone regeneration and long‐term peri‐implant stability, while customized CAD/CAM titanium meshes were associated with reduced operative time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumAlveolar Ridge AugmentationSurgical MeshBone ScrewsBone TransplantationHumansRetrospective StudiesFemaleCone-Beam Computed TomographyMaleMiddle AgedComputer-Aided DesignTreatment OutcomeDental Implantation, EndosseousAgedAdultCollagen

Stichwörter der Autor:innen

alveolar ridge augmentationbone substitutescomputer‐aided designcone‐beam computed tomographydental implantsguided bone regenerationtitanium mesh

Substanzen

TitaniumCollagen

Autor:innen und Institutionen

  • Department of Surgical Sciences and Integrated Diagnostics, University of Genoa DISC, Genova, Italy.

ORCID-Profile: M Menini, P Pesce, N De Angelis

Zitieren

APA

Wurtz, G., Bagnasco, F., Menini, M., Pesce, P., Baldi, D., & De Angelis, N. (2026). Clinical and Radiographic Outcomes of Customized Titanium Mesh vs. Screw Tent‐Pole Grafting: A Retrospective Study. Clinical Implant Dentistry and Related Research, 28(2). https://doi.org/10.1111/cid.70139

Vancouver

Wurtz G, Bagnasco F, Menini M, Pesce P, Baldi D, De Angelis N. Clinical and Radiographic Outcomes of Customized Titanium Mesh vs. Screw Tent‐Pole Grafting: A Retrospective Study. Clinical Implant Dentistry and Related Research. 2026;28(2). doi:10.1111/cid.70139

BibTeX
@article{Wurtz2026,
  author = {Wurtz, G and Bagnasco, F and Menini, M and Pesce, P and Baldi, D and De Angelis, N},
  title = {Clinical and Radiographic Outcomes of Customized Titanium Mesh vs. Screw Tent‐Pole Grafting: A Retrospective Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2026},
  volume = {28},
  number = {2},
  doi = {10.1111/cid.70139}
}
Kostenlos starten →