EUVIMEDEUVIMED entdecken
Vergleichsstudie

Reduced Surgical Complications in Graft‐Masked 3D Ti Mesh for Alveolar Augmentation: A Retrospective Comparative Study

Hui Gao, Dan Chen, Chao Wang iD, Lingling Zheng, Chunjuan Wang, Liya Ai, Antonio Apicella iD, Yubo Fan

Clinical Implant Dentistry and Related Research · 2025-12 · 27 (6)

DOI: 10.1111/cid.70099 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 28.10.2025. Verfasst von Hui Gao und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Affiliated Stomatological Hospital of Chongqing Medical University, Chongqing Key Laboratory of Oral Diseases, Chongqing Municipal Key Laboratory…. Hauptthemen laut MEDLINE: Titanium, Surgical Mesh, Alveolar Ridge Augmentation, Printing, Three-Dimensional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: The National Natural Science Foundation of China, Beijing Natural Science Foundation, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess and compare the effectiveness of different bone grafting techniques, including unmasked meshes and graft‐masked meshes approaches, for augmenting alveolar bone defects using 3D‐printed titanium mesh (3D‐TM). Materials and Methods This retrospective study included 34 patients (69 teeth with alveolar bone defects) who underwent guided bone regeneration (GBR) using 3D‐printed titanium mesh (3D‐TM). Patients were assigned to two groups: the unmasked meshes group ( n = 17, 34 treatment sites) and the graft‐masked meshes group ( n = 17, 35 treatment sites). Cone beam computed tomography (CBCT) data of pre‐ and post‐operative 3D‐TM implantation were digitally reconstructed, with a minimum 6‐month follow‐up period. Clinical outcomes included titanium mesh exposure rates, pseudo‐periosteum rates, and osteogenic efficiency metrics such as bone volume, vertical bone height/width, and bone contour. Bone volume was analyzed using samples t ‐tests, vertical bone height/width was analyzed using a generalized estimating equations (GEE) model, and bone contour was analyzed using the Mann–Whitney U test. Categorical outcomes were evaluated via Fisher's exact probability test.

Results

Clinical complications analysis revealed distinct outcomes between the two groups. Titanium mesh exposure occurred in 7 cases overall, with no statistically significant difference between the unmasked meshes group (5/17, 29.4%) and the graft‐masked meshes group (2/17, 11.8%) (Fisher's exact test, p = 0.398). In contrast, pseudo‐periosteum demonstrated a significant discrepancy, observed in 14/17 cases (82.4%) in the unmasked meshes group compared to 4/17 cases (23.5%) in the graft‐masked meshes group (Fisher's exact test, p = 0.002). Notably, no infections occurred in either group. Analysis of osteogenic efficacy revealed significant intergroup differences in bone volume ratio (Independent samples t ‐test, df = 32, p < 0.05), vertical bone height ratio, and width ratio (GEE, df = 1, p < 0.05), and bone contour accuracy at the minimum and 25% percentiles (Mann–Whitney U test, p < 0.05). No significant differences were observed at the 50%, 75% percentile, or maximum value.

Conclusion

The graft‐masked meshes technique in 3D‐TM guided bone regeneration surgery is a reliable and effective method for augmenting alveolar bone defects. This method effectively reduces procedure‐related complications, including titanium mesh exposure and pseudo‐periosteum, thereby improving osteogenic efficacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumSurgical MeshAlveolar Ridge AugmentationPrinting, Three-DimensionalPostoperative ComplicationsBone TransplantationHumansRetrospective StudiesMaleFemaleMiddle AgedCone-Beam Computed TomographyAdultAgedAlveolar Bone Loss

Stichwörter der Autor:innen

3D‐printed titanium meshbone grafting techniquedigital reconstructionguided bone regenerationosteogenic efficiency

Substanzen

Titanium

Autor:innen und Institutionen

  • The Affiliated Stomatological Hospital of Chongqing Medical University, Chongqing Key Laboratory of Oral Diseases, Chongqing Municipal Key Laboratory of Oral Biomedical Engineering Education, Chongqing Municipal Health…
  • Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology…
  • Department of Architecture and Industrial Design, Advanced Materials Lab, University of Campania, Aversa, Italy.

ORCID-Profile: Chao Wang, Antonio Apicella

Förderung

  • The National Natural Science Foundation of China
  • Beijing Natural Science Foundation
  • Fundamental Research Funds for the Central Universities
  • State Key Laboratory Of Oral Diseases
  • the Affiliated Stomatological Hospital of Chongqing Medical University
  • Chongqing Municipal Health Commission
  • Chongqing Municipal Science and Technology Bureau
  • National Natural Science Foundation of China

Zitieren

APA

Gao, H., Chen, D., Wang, C., Zheng, L., Wang, C., Ai, L., Apicella, A., & Fan, Y. (2025). Reduced Surgical Complications in Graft‐Masked 3D Ti Mesh for Alveolar Augmentation: A Retrospective Comparative Study. Clinical Implant Dentistry and Related Research, 27(6). https://doi.org/10.1111/cid.70099

Vancouver

Gao H, Chen D, Wang C, Zheng L, Wang C, Ai L, et al. Reduced Surgical Complications in Graft‐Masked 3D Ti Mesh for Alveolar Augmentation: A Retrospective Comparative Study. Clinical Implant Dentistry and Related Research. 2025;27(6). doi:10.1111/cid.70099

BibTeX
@article{Gao2025,
  author = {Gao, Hui and Chen, Dan and Wang, Chao and Zheng, Lingling and Wang, Chunjuan and Ai, Liya and Apicella, Antonio and Fan, Yubo},
  title = {Reduced Surgical Complications in Graft‐Masked 3D Ti Mesh for Alveolar Augmentation: A Retrospective Comparative Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  volume = {27},
  number = {6},
  doi = {10.1111/cid.70099}
}
Kostenlos starten →