EUVIMEDEUVIMED entdecken
Crossref

Accuracy of Robotic Vesus Fully Guided Static Computer‐Assisted Implant Surgery With Transcrestal Sinus Floor Elevation

Qinmeng Zhang, Yuesheng Qiu, Ling Hu, Danhong Zhou, Zichun Xia, Guoli Yang iD, Zhiwei Jiang iD

Clinical Implant Dentistry and Related Research · 2025

DOI: 10.1111/cid.70113 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2025. Verfasst von Qinmeng Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, …. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Dental Implantation, Endosseous, Robotic Surgical Procedures, Sinus Floor Augmentation. Die Arbeit nennt 46 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Health Department of Zhejiang Province Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the accuracy of dental implant placement using fully guided static computer‐assisted implant surgery (s‐CAIS) and autonomous robotic computer‐assisted implant surgery (r‐CAIS) technology in patients with transcrestal sinus floor elevation. Materials and Methods Patients with posterior teeth loss and transcrestal sinus floor elevation using s‐CAIS or r‐CAIS technology for implant surgery were included in this study. A total of 34 patients with 42 implants were included in the study (17 patients with 19 implants in the autonomous r‐CAIS group, 17 patients with 23 implants in the fully guided s‐CAIS group). Postoperative cone‐beam computed tomography (CBCT) scans were used to determine the discrepancies between the planned and actually placed implants. The preoperative and postoperative CBCT were utilized to estimate the linear deviations and angular deviations in two‐dimensional (2D) and three‐dimensional (3D) space.

Results

A total of 42 implants were included, with significant differences between the autonomous r‐CAIS group and fully guided s‐CAIS group ( p < 0.001). No adverse surgical events occurred. The 3D deviations at the implant platform were 0.484 ± 0.218 mm for the autonomous r‐CAIS group and 1.179 ± 0.776 mm for the fully guided s‐CAIS group, respectively. The mean linear deviations at the implant apex were 0.527 ± 0.247 and 1.196 ± 0.830 mm, respectively. The mean angular deviation was 0.882° ± 0.967° for the autonomous r‐CAIS group and 2.478° ± 1.524° for the fully guided s‐CAIS group.

Conclusions

Autonomous r‐CAIS technology provided a more accurate surgical approach for implant placement in patients with transcrestal sinus floor elevation than fully guided s‐CAIS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedDental Implantation, EndosseousRobotic Surgical ProceduresSinus Floor AugmentationHumansFemaleMaleCone-Beam Computed TomographyMiddle AgedAdultAgedDental Implants

Stichwörter der Autor:innen

accuracyrobot‐assisted implant surgerystatic computer guide implant surgerytranscrestal sinus floor elevation

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Zhejiang Key Laboratory of Oral Biomedical, Hangzhou, China.
  • Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China.

ORCID-Profile: Guoli Yang, Zhiwei Jiang

Förderung

  • National Natural Science Foundation of China
  • Health Department of Zhejiang Province Fund

Zitieren

APA

Zhang, Q., Qiu, Y., Hu, L., Zhou, D., Xia, Z., Yang, G., & Jiang, Z. (2025). Accuracy of Robotic Vesus Fully Guided Static Computer‐Assisted Implant Surgery With Transcrestal Sinus Floor Elevation. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.70113

Vancouver

Zhang Q, Qiu Y, Hu L, Zhou D, Xia Z, Yang G, et al. Accuracy of Robotic Vesus Fully Guided Static Computer‐Assisted Implant Surgery With Transcrestal Sinus Floor Elevation. Clinical Implant Dentistry and Related Research. 2025. doi:10.1111/cid.70113

BibTeX
@article{Zhang2025,
  author = {Zhang, Qinmeng and Qiu, Yuesheng and Hu, Ling and Zhou, Danhong and Xia, Zichun and Yang, Guoli and Jiang, Zhiwei},
  title = {Accuracy of Robotic Vesus Fully Guided Static Computer‐Assisted Implant Surgery With Transcrestal Sinus Floor Elevation},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  doi = {10.1111/cid.70113}
}
Kostenlos starten →