Peri‐Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study
Clinical Implant Dentistry and Related Research · 2025
DOI: 10.1111/cid.70083 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, 2025. Verfasst von Manon Borie und 6 weiteren Autor:innen. Beteiligte Einrichtung: Dental Biomaterials Research Unit, Faculty of Medicine, University of Liège, Liège, Belgium. Hauptthemen laut MEDLINE: Dental Abutments, Dental Implants, Gingiva, Dental Materials. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: International Team for Implantology, Research Council of Norway, Norges Forskningsråd.
Abstract (Originalsprache)
Background
The peri‐implant soft tissue integration is critical to maintain peri‐implant health and the long‐term success of dental implant rehabilitations.
Aim
This comparative histomorphometry study aims to characterize the peri‐implant soft tissues (PIST) around experimental abutments made of titanium (Ti), dental resin (Re), and polyetheretherketone (PEEK).
Methods
Thirty bone‐level implants were placed, each receiving an experimental transmucosal healing abutment made of one of the three materials. After an 8‐week healing period, the abutments and surrounding tissues were harvested and prepared for histological and histomorphometric analyses. Dimensions of sulcus depth, epithelial and connective tissue adhesion were measured. In addition, the abutment surface characteristics, levels of inflammation, plaque accumulation, and peri‐implant bone level changes were evaluated.
Results
The dimensions of the different components of the PIST were comparable across the three experimental groups. The mean overall dimensions of the PIST were 2.68 ± 0.51 mm for Ti, 2.66 ± 0.47 mm for Re, and 2.32 ± 0.55 mm for PEEK. Mean sulcus depth was 0.71 ± 0.69 mm for Ti, 0.74 ± 0.50 mm for Re, and 0.68 ± 0.63 mm for PEEK. Mean junctional epithelium was 1.82 ± 0.67 mm for Ti, 1.56 ± 0.47 mm for Re, and 1.53 ± 0.40 mm for PEEK. Mean harvested connective tissue (until abutment platform) was 0.30 ± 0.29 mm for Ti, 0.36 ± 0.38 mm for Re, and 0.09 ± 0.10 mm for PEEK. However, the resin group exhibited significantly more supramucosal biofilm adhesion ( p = 0.026).
Conclusion
The PIST around abutments made of PEEK, resin, or titanium tend to develop in a similar pattern. However, longer observation periods are required to evaluate the long‐term effects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Dental Biomaterials Research Unit, Faculty of Medicine, University of Liège, Liège, Belgium.
- Robert K. Schenk Laboratory of Oral Histology, School of Dental Medicine, University of Bern, Bern, Switzerland.
- Department of Periodontology, Oro-Dental and Implant Surgery Faculty of Medicine, University of Liège, CHU of Liège, Liège, Belgium.
- Department of Biomaterials, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Oslo, Norway.
- Oro-Dental and Implant Surgery Faculty of Medicine, University of Liège, CHU of Liège, Liège, Belgium.
ORCID-Profile: Håvard Jostein Haugen
Förderung
- International Team for Implantology
- Research Council of Norway
- Norges Forskningsråd
Zitieren
APA
Borie, M., Bosshardt, D., Liegeois, L., Lecloux, G., Jostein Haugen, H., Van Hede, D., & Lambert, F. (2025). Peri‐Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.70083
Vancouver
Borie M, Bosshardt D, Liegeois L, Lecloux G, Jostein Haugen H, Van Hede D, et al. Peri‐Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study. Clinical Implant Dentistry and Related Research. 2025. doi:10.1111/cid.70083
BibTeX
@article{Borie2025,
author = {Borie, Manon and Bosshardt, Dieter and Liegeois, Lemmy and Lecloux, Geoffrey and Jostein Haugen, Håvard and Van Hede, Dorien and Lambert, France},
title = {Peri‐Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study},
journal = {Clinical Implant Dentistry and Related Research},
year = {2025},
doi = {10.1111/cid.70083}
}
EUVIMED