Zirconia, titanium, and polyetheretherketone implant abutments show equal long‐term clinical success—A systematic review and network meta‐analysis
Periodontology 2000 · 2025
DOI: 10.1111/prd.70018 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Periodontology 2000, 2025. Verfasst von Yasir Nabeel Al-Mohammad und 13 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Translational Medicine, Semmelweis University, Budapest, Hungary. Hauptthemen laut MEDLINE: Titanium, Zirconium, Benzophenones, Polyethylene Glycols. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Nemzeti Kutatási, Fejlesztési és Innovaciós Alap.
Abstract (Originalsprache)
Hundreds of millions of people have one or more missing teeth. Consequently, a substantial number of patients undergo implant therapy each year. However, technical complications and soft tissue inflammation associated with the implant abutment or the type of restoration can lead to bone loss and, ultimately, implant failure. Using the methodology of network meta‐analysis to rigorously compare and contrast the clinical performance of the three commonly used abutment materials: titanium (Ti), zirconium (Zr), and polyetheretherketone (PEEK) polymer. Until May 2025, a systematic search was performed in MEDLINE (PubMed), EMBASE, Scopus, and CENTRAL to find clinical studies comparing Ti, Zr, and PEEK implant abutments. Case reports, case series, in vitro, and in vivo studies were excluded. The Risk of Bias Tool 2, ROBINS‐I, and GRADE approaches were used for quality and certainty assessment. Thirty‐four articles (950 patients) were included, with various follow‐ups. All abutments had high survival rates and no significant differences in marginal bone loss (BL), probing depth (PD), bleeding on probing (BOP), and plaque index (PI). There was no significant difference between Zr and Ti for papillary index (PAP), with a general trend toward better results in Zr, which may be of clinical significance. There was a statistically significant difference in soft tissue discoloration (ΔE) values and technical complications of Zr versus Ti [MD: −2.03, CI: −3.89 to −0.18] and [OR: 0.26, CI: 0.09 to 0.72], respectively, indicating better esthetics and fewer technical complications in Zr. Both Ti and Zr are clinically successful and biologically acceptable. PEEK abutments demonstrated comparable characteristics with both Ti and Zr. However, more studies about PEEK and cost‐effectiveness analyses should also be performed to find the best options for clinical applications. PEEK can be a good alternative to Ti and Zr abutments for single‐tooth replacement in the anterior and premolar regions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
- Department of Restorative Dentistry and Endodontics, Semmelweis University, Budapest, Hungary.
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary.
- Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Budapest, Hungary.
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary.
- Department of Periodontology, Semmelweis University, Budapest, Hungary.
ORCID-Profile: Gábor Varga
Förderung
- Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
Zitieren
APA
Al-Mohammad, Y. N., Kelly, C., Martinekova, P., Wenning, A. S., Kiss-Dala, S., Gede, N., Kerémi, B., Németh, Z., Hermann, P., Czumbel, L. M., Mikulás, K., Hegyi, P., Sculean, A., & Varga, G. (2025). Zirconia, titanium, and polyetheretherketone implant abutments show equal long‐term clinical success—A systematic review and network meta‐analysis. Periodontology 2000. https://doi.org/10.1111/prd.70018
Vancouver
Al-Mohammad YN, Kelly C, Martinekova P, Wenning AS, Kiss-Dala S, Gede N, et al. Zirconia, titanium, and polyetheretherketone implant abutments show equal long‐term clinical success—A systematic review and network meta‐analysis. Periodontology 2000. 2025. doi:10.1111/prd.70018
BibTeX
@article{AlMohammad2025,
author = {Al-Mohammad, Yasir Nabeel and Kelly, Caroline and Martinekova, Petrana and Wenning, Alexander Schulze and Kiss-Dala, Szilvia and Gede, Noémi and Kerémi, Beáta and Németh, Zsolt and Hermann, Péter and Czumbel, László Márk and Mikulás, Krisztina and Hegyi, Péter and Sculean, Anton and Varga, Gábor},
title = {Zirconia, titanium, and polyetheretherketone implant abutments show equal long‐term clinical success—A systematic review and network meta‐analysis},
journal = {Periodontology 2000},
year = {2025},
doi = {10.1111/prd.70018}
}
EUVIMED