EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of Photogrammetry, Intraoral Scanning, and Conventional Impression for Multiple Implants: An In Vitro Study

Mingyue Lyu, Yizhou Li, Dingyi Xu, Qi Xing, Shiwen Zhang, Quan Yuan iD

Clinical Implant Dentistry and Related Research · 2025-02 · 27 (1)

DOI: 10.1111/cid.13419 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 21.11.2024. Verfasst von Mingyue Lyu und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of…. Hauptthemen laut MEDLINE: Photogrammetry, Dental Impression Technique, Dental Implants. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 70 Literaturangaben. Gefördert von: Beijing Natural Science Foundation, Young Clinical Research Fund of the Chinese Stomatological Association, Sichuan Science and Technology Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This in vitro study compared the accuracy of conventional impressions (CNVs), photogrammetry (PG), and intraoral scanning (IOS) for recording implant impressions of edentulous segments, ranging from part to complete arches by different evaluation methods.

Methods

The master model for an edentulous maxillary arch was created with six implants (a–f). CNVs, PG, and IOS were used for impressions. Three impression ranges (bcde, bcdef, and abcdef) were chosen for analysis. The best‐fit algorithm, absolute linear deviation, and angular deviation were used for evaluation. Trueness and precision were analyzed by two‐way ANOVA and the Kruskal–Wallis test, respectively.

Results

The accuracy of multiple implant impressions was significantly influenced by the impression method and impression range ( p < 0.05) regardless of the evaluation methods used. At smaller ranges (bcde and bcdef), there was no difference in the trueness of the three impression methods, whereas at a larger range (abcdef), both PG and CNV exhibited similar trueness, which was significantly higher than that of IOS( p < 0.05). The precision of PG was significantly better than that of CNV and IOS in most of cases ( p < 0.05). As the range expanded, the trueness and precision of PG and IOS decreased ( p < 0.05), whereas the accuracy of CNV remained stable.

Conclusions

In the case of large‐range impressions, PG demonstrated a similar degree of trueness and better precision compared with CNVs, whereas the trueness and precision of the intraoral scanning were worse. This indicated that PG might be a promising method for multiple implant impressions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryDental Impression TechniqueDental ImplantsHumansIn Vitro TechniquesModels, DentalMaxilla

Stichwörter der Autor:innen

absolute linear deviation methodaccuracyangular deviationbest‐fit algorithmconventional impressionintraoral scanningphotogrammetry

Substanzen

Dental Implants

Autor:innen und Institutionen

  • State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
  • Department of Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China.

ORCID-Profile: Quan Yuan

Förderung

  • Beijing Natural Science Foundation
  • Young Clinical Research Fund of the Chinese Stomatological Association
  • Sichuan Science and Technology Program
  • Natural Science Foundation of Beijing Municipality

Zitieren

APA

Lyu, M., Li, Y., Xu, D., Xing, Q., Zhang, S., & Yuan, Q. (2025). Accuracy of Photogrammetry, Intraoral Scanning, and Conventional Impression for Multiple Implants: An In Vitro Study. Clinical Implant Dentistry and Related Research, 27(1). https://doi.org/10.1111/cid.13419

Vancouver

Lyu M, Li Y, Xu D, Xing Q, Zhang S, Yuan Q. Accuracy of Photogrammetry, Intraoral Scanning, and Conventional Impression for Multiple Implants: An In Vitro Study. Clinical Implant Dentistry and Related Research. 2025;27(1). doi:10.1111/cid.13419

BibTeX
@article{Lyu2025,
  author = {Lyu, Mingyue and Li, Yizhou and Xu, Dingyi and Xing, Qi and Zhang, Shiwen and Yuan, Quan},
  title = {Accuracy of Photogrammetry, Intraoral Scanning, and Conventional Impression for Multiple Implants: An In Vitro Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  volume = {27},
  number = {1},
  doi = {10.1111/cid.13419}
}
Kostenlos starten →