Comparative analysis of dental implant placement accuracy: Semi‐active robotic versus free‐hand techniques: A randomized controlled clinical trial
Clinical Implant Dentistry and Related Research · 2024-12 · 26 (6) · 1149-1161
DOI: 10.1111/cid.13375 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 19.08.2024. Verfasst von Fan Yang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou…. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Robotic Surgical Procedures. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Major Scientific and Technological Project of Zhejiang Province.
Abstract (Originalsprache)
Background
Robot‐assisted implant surgery has emerged as a novel digital technology, and the accuracy need further assessment.
Purpose
This study aimed to compare the accuracy of single dental implant placement between a novel semi‐active robot‐assisted implant surgery (RAIS) method and the conventional free‐hand implant surgery (FHIS) method through a multicenter, randomized controlled clinical trial. Materials and Methods Patients requiring single dental implant placement were recruited and randomized into RAIS and FHIS group. Deviations at the platform, apex, and angle between the planned and final implant positions were assessed in both groups. Additionally, the evaluation of instrument and surgical complications was examined.
Results
A total of 140 patients (median age: 35.35 ± 12.55 years; 43 males, 97 females) with 140 implants from four different research centers were included, with 70 patients (70 implants) in the RAIS group and 70 patients (70 implants) in the FHIS group. In the RAIS and FHIS groups, the median platform deviations were 0.76 ± 0.36 mm and 1.48 ± 0.93 mm, respectively ( p < 0.001); median apex deviations were 0.85 ± 0.48 mm and 2.14 ± 1.25 mm, respectively ( p < 0.001); and median angular deviations were 2.05 ± 1.33° and 7.36 ± 4.67°, respectively ( p < 0.001). Similar significant difference also presented between RAIS and FHIS group in platform vertical/horizontal deviation, apex vertical/horizontal deviation. Additionally, implants with self‐tapping characteristics exhibited significantly larger deviations compared with those without self‐tapping characteristics in the RAIS group. Both RAIS and FHIS methods demonstrated comparable morbidity and safety pre‐ and post‐operation.
Conclusions
The results indicated that the RAIS method demonstrated superior accuracy in single dental implant placement compared with the FHIS method. Specifically, RAIS exhibited significantly smaller deviations in platform, apex, and angular positions, as well as platform and apex vertical/horizontal deviations. This clinical trial was not registered prior to participant recruitment and randomization. https://www.chictr.org.cn/showproj.html?proj=195045 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, China.
- Department of Stomatology, Zhejiang Chinese Medicine University, Hangzhou, China.
- Department of Stomatology, Hangzhou Normal University, Hangzhou, China.
- Shanghai Perioimplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China.
- Jiangxi Province Key Laboratory of Oral Biomedicine, Jiangxi Province Clinical Research Center for Oral Diseases, The Affiliated Stomatological Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.
ORCID-Profile: Fan Yang, Yude Ding, Linhong Wang
Förderung
- Major Scientific and Technological Project of Zhejiang Province
Zitieren
APA
Yang, F., Chen, J., Cao, R., Tang, Q., Liu, H., Zheng, Y., Liu, B., Huang, M., Wang, Z., Ding, Y., & Wang, L. (2024). Comparative analysis of dental implant placement accuracy: Semi‐active robotic versus free‐hand techniques: A randomized controlled clinical trial. Clinical Implant Dentistry and Related Research, 26(6), 1149-1161. https://doi.org/10.1111/cid.13375
Vancouver
Yang F, Chen J, Cao R, Tang Q, Liu H, Zheng Y, et al. Comparative analysis of dental implant placement accuracy: Semi‐active robotic versus free‐hand techniques: A randomized controlled clinical trial. Clinical Implant Dentistry and Related Research. 2024;26(6):1149-1161. doi:10.1111/cid.13375
BibTeX
@article{Yang2024,
author = {Yang, Fan and Chen, Jianping and Cao, Ruijue and Tang, Qingwei and Liu, Haiyan and Zheng, Yuchen and Liu, BeiLei and Huang, Min and Wang, Zhenshi and Ding, Yude and Wang, Linhong},
title = {Comparative analysis of dental implant placement accuracy: Semi‐active robotic versus free‐hand techniques: A randomized controlled clinical trial},
journal = {Clinical Implant Dentistry and Related Research},
year = {2024},
volume = {26},
number = {6},
pages = {1149--1161},
doi = {10.1111/cid.13375}
}