Accuracy of digital and conventional implant‐level impression techniques for maxillary full‐arch screw‐retained prosthesis: A crossover randomized trial
Clinical Implant Dentistry and Related Research · 2024-08 · 26 (4) · 714-723
DOI: 10.1111/cid.13336 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 10.05.2024. Verfasst von Ammar Ghanim Jasim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Iraqi Ministry of Health, Baghdad, Iraq. Hauptthemen laut MEDLINE: Dental Impression Technique, Maxilla. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
Objectives
This study aimed to compare the accuracy of implant‐level conventional and digital impressions for atrophied maxillary ridges. Materials and Methods Twelve participants with atrophied edentulous maxillary ridges received six implants. Six months later and after soft tissue maturation around healing abutments, a control cast was constructed using the final passive restoration for each patient. Two types of implant‐level impression techniques were carried out for each patient: (1) conventional (splinted open‐tray) impression technique and (2) digital impression technique. For both techniques, scan bodies were labeled from the most distal implant on the left side (A, B, C, D, E, and F) and scanning was made. Accuracy of both techniques was measured using in vitro (two‐dimensional and three‐dimensional) and in vivo (clinical) methods. Two‐dimensional methods include measurement of the difference in linear distances AB, AC AD, AE, and AF. Geomagic software was used to assess the three‐dimensional deviation between the two impression techniques using the superimposition of standard tessellation language files. The incidence and percentage of nonpassive frameworks and framework misfits of final restorations for both types of impression techniques were assessed using the single screw test.
Results
For all distances, digital impressions recorded significantly higher deviation from control measurements than conventional impressions. The highest two‐dimensional linear deviation was noted for AF distance and the lowest difference was noted for AB distance. For all scan bodies, digital impressions recorded significantly higher three‐dimensional deviation than conventional impressions. The highest three‐dimensional deviation was noted with scan bodies C and D. Digital impressions recorded a significantly higher incidence of nonpassive frameworks and framework misfits than conventional impressions. [Correction added on 11 June 2024, after first online publication: In the preceding sentence, “digital impressions” was changed to “conventional impressions” in this version.]
Conclusion
Within the limitations of this study, it could be concluded that the conventional implant‐level impression technique showed greater in vitro and in vivo accuracy than the digital impression technique when used for full‐arch maxillary fixed restorations on inclined implants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Iraqi Ministry of Health, Baghdad, Iraq.
- Prosthodontics, MTI University, Cairo, Egypt.
- Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
ORCID-Profile: Gilan Y Altonbary
Zitieren
APA
Jasim, A. G., Abo Elezz, M. G., Altonbary, G. Y., & Elsyad, M. A. (2024). Accuracy of digital and conventional implant‐level impression techniques for maxillary full‐arch screw‐retained prosthesis: A crossover randomized trial. Clinical Implant Dentistry and Related Research, 26(4), 714-723. https://doi.org/10.1111/cid.13336
Vancouver
Jasim AG, Abo Elezz MG, Altonbary GY, Elsyad MA. Accuracy of digital and conventional implant‐level impression techniques for maxillary full‐arch screw‐retained prosthesis: A crossover randomized trial. Clinical Implant Dentistry and Related Research. 2024;26(4):714-723. doi:10.1111/cid.13336
BibTeX
@article{Jasim2024,
author = {Jasim, Ammar Ghanim and Abo Elezz, Mona Galal and Altonbary, Gilan Y and Elsyad, Moustafa Abdou},
title = {Accuracy of digital and conventional implant‐level impression techniques for maxillary full‐arch screw‐retained prosthesis: A crossover randomized trial},
journal = {Clinical Implant Dentistry and Related Research},
year = {2024},
volume = {26},
number = {4},
pages = {714--723},
doi = {10.1111/cid.13336}
}
EUVIMED