EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Three‐Dimensional Transjugular Intrahepatic Portosystemic Shunt Geometry Predicts Shunt Dysfunction

Carsten Meyer, Markus Kimmann iD, Katharina Böhm, Sebastian Nowak, Alba Maria Paar Pérez, Jörn Arne Meier, Sara Noemi Reinartz Groba, Juliana Gödiker iD, Frank Erhard Uschner, Feras Sanoubara, Johannes Chang, Jonel Trebicka iD and 2 more

Alimentary Pharmacology & Therapeutics · 2025

DOI: 10.1111/apt.70133 ↗

At a glance

Journal article in Alimentary Pharmacology & Therapeutics, 2025. Written by Carsten Meyer and 13 co-authors. Institution: Department of Diagnostic and Interventional Radiology, University of Bonn, Bonn, Germany. Major MEDLINE topics: Portasystemic Shunt, Transjugular Intrahepatic, Hypertension, Portal, Liver Cirrhosis. Cited 9 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY 4.0). Funded by: Ernst-und-Berta Grimmke Foundation, Else-Kröner Fresenius Foundation, BONFOR research program of the University of Bonn.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Patients with decompensated cirrhosis are at risk of portal hypertension‐related complications, such as refractory ascites or variceal bleeding. Transjugular intrahepatic portosystemic shunt (TIPS) insertion is the most effective treatment to reduce portal hypertension. However, patients are at risk for TIPS dysfunction.

Aims

We aimed to investigate the prognostic value of three‐dimensional (3D) TIPS geometry in predicting TIPS dysfunction.

Methods

A total of 107 patients who underwent TIPS insertion between 2014 and 2019 and received a computed tomography (CT) scan after TIPS insertion during routine clinical practice were included. We used a semiautomated algorithm and multiplanar reconstructions of these CT scans to calculate parameters of 3D TIPS geometry. The primary outcome of this study was the development of TIPS dysfunction (defined as need for invasive TIPS revision). To identify predictors for the development of TIPS dysfunction, Cox regression analyses were performed with TIPS dysfunction as the endpoint.

Results

Thirty‐two patients developed TIPS dysfunction and were compared to the dysfunction‐free 75 patients. A larger distance from the cranial TIPS stent end to the vena cava inferior ( p < 0.001, HR 1.061, 95% CI 1.030–1.093) and the maximum stent curvature ( p = 0.003, HR 1.020, 95% CI 1.007–1.034) were significantly associated with TIPS dysfunction in a multivariate Cox regression analysis.

Conclusion

A more pronounced stent curvature and a longer cranial stent distance from the inferior vena cava were identified as independent predictors of TIPS dysfunction. Interventionalists should choose a more central and less curved TIPS tract during the TIPS procedure to reduce the risk of development of TIPS dysfunction. Trial Registration This retrospective monocentric study includes patients from the NEPTUN cohort (registered at ClinicalTrials.gov; Identifier: NCT03628807).

Subjects

MeSH terms (MEDLINE)

Portasystemic Shunt, Transjugular IntrahepaticHypertension, PortalLiver CirrhosisHumansFemaleMaleMiddle AgedAgedTomography, X-Ray ComputedRetrospective StudiesImaging, Three-DimensionalPrognosisAdult

Author keywords

cirrhosisportal hypertensiontransjugular intrahepatic portosystemic shunt

Authors and institutions

  • Department of Diagnostic and Interventional Radiology, University of Bonn, Bonn, Germany.
  • Department of Internal Medicine B, University of Münster, Münster, Germany.
  • Department of Internal Medicine I, University of Bonn, Bonn, Germany.
  • European Foundation for the Study of Chronic Liver Failure-EF CLIF, Barcelona, Spain.

ORCID profiles: Markus Kimmann, Juliana Gödiker, Jonel Trebicka, Michael Praktiknjo

Funding

  • Ernst-und-Berta Grimmke Foundation
  • Else-Kröner Fresenius Foundation
  • BONFOR research program of the University of Bonn

Cite

APA

Meyer, C., Kimmann, M., Böhm, K., Nowak, S., Pérez, A. M. P., Meier, J. A., Reinartz Groba, S. N., Gödiker, J., Uschner, F. E., Sanoubara, F., Chang, J., Trebicka, J., Sprinkart, A. M., & Praktiknjo, M. (2025). Three‐Dimensional Transjugular Intrahepatic Portosystemic Shunt Geometry Predicts Shunt Dysfunction. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/apt.70133

Vancouver

Meyer C, Kimmann M, Böhm K, Nowak S, Pérez AMP, Meier JA, et al. Three‐Dimensional Transjugular Intrahepatic Portosystemic Shunt Geometry Predicts Shunt Dysfunction. Alimentary Pharmacology & Therapeutics. 2025. doi:10.1111/apt.70133

BibTeX
@article{Meyer2025,
  author = {Meyer, Carsten and Kimmann, Markus and Böhm, Katharina and Nowak, Sebastian and Pérez, Alba Maria Paar and Meier, Jörn Arne and Reinartz Groba, Sara Noemi and Gödiker, Juliana and Uschner, Frank Erhard and Sanoubara, Feras and Chang, Johannes and Trebicka, Jonel and Sprinkart, Alois Martin and Praktiknjo, Michael},
  title = {Three‐Dimensional Transjugular Intrahepatic Portosystemic Shunt Geometry Predicts Shunt Dysfunction},
  journal = {Alimentary Pharmacology & Therapeutics},
  year = {2025},
  doi = {10.1111/apt.70133}
}
Start for free →