EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effectiveness of controlled-expansion transjugular intrahepatic portosystemic shunt (CX-TIPS) in an interdisciplinary setting at a large tertiary center

Marlene Hintersteininger, Julia Kappel, Theresa Müllner-Buscics, Susanna Riegler, Nina Dominik, Georg Kramer, Christian Sebesta, Paul Thöne, Albert Friedrich Stättermayer, Lukas Reider, Maria Schoder, Catharina Klausenitz und 6 weitere

Wiener klinische Wochenschrift · 2025

DOI: 10.1007/s00508-025-02606-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wiener klinische Wochenschrift, 2025. Verfasst von Marlene Hintersteininger und 17 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Portasystemic Shunt, Transjugular Intrahepatic, Hypertension, Portal, Liver Cirrhosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ludwig Boltzmann Gesellschaft, Österreichische Gesellschaft für Gastroenterologie und Hepatologie, Medical University of Vienna.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The use of controlled-expansion transjugular intrahepatic portosystemic shunt (CX-TIPS) effectively controls portal hypertension (PH)-related complications while reducing risks related to fully expanded stents. We evaluated the effectiveness of CX-TIPS in a large Viennese patient cohort.

Method

We assessed the number of patients evaluated for CX-TIPS placement by interdisciplinary discussion at the Medical University of Vienna and included all patients from the prospective AUTIPS registry undergoing CX-TIPS placement between June 2018 – December 2024. After clinical and laboratory characterization at baseline, patients were followed up for clinical events.

Results

Overall, 200 patients underwent interdisciplinary evaluation for CX-TIPS. In 62.5% CX-TIPS was recommended and 82.4% of these patients underwent CX-TIPS placement. Among 103 patients with CX-TIPS placement between June 2018 – December 2024 (median age 57 years, 67.0% male, median MELD 11), the primary indication for CX-TIPS implantation was ascites (65.0%). The median portal pressure gradient decreased from 18 mm Hg to 8 mm Hg after CX-TIPS. Underdilated CX-TIPS placement was performed in 13.6% ( n = 14) of patients and portal vein recanalization (PVR-TIPS) was performed in 4 patients. During a median follow-up time of 13.5 months, 30.1% of patients experienced hepatic encephalopathy and 5.8% cardiac decompensation. Kaplan-Meier survival analyses revealed 1‑year and 3‑year transplant-free survival rates of 78.0% and 74.7%, respectively.

Conclusion

Implementation of interdisciplinary case discussions and the use of CX-TIPS enable personalized medicine in patients with cirrhosis. Underdilation of CX-TIPS should be considered in patients at high risk for complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Portasystemic Shunt, Transjugular IntrahepaticHypertension, PortalLiver CirrhosisHumansMaleFemaleMiddle AgedAustriaTreatment OutcomeTertiary Care CentersAgedAdultProspective Studies

Stichwörter der Autor:innen

AscitesCollateralsInterdisciplinary boardPortal hypertensionSurvivalVariceal bleeding

Autor:innen und Institutionen

  • Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Vienna Hepatic Hemodynamic Lab, Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Clinical Research Group MOTION, Medical University of Vienna, Vienna, Austria.
  • Christian Doppler Lab for Portal Hypertension and Liver Fibrosis, Medical University of Vienna, Vienna, Austria.
  • Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria. thomas.reiberger@meduniwien.ac.at.

Förderung

  • Ludwig Boltzmann Gesellschaft
  • Österreichische Gesellschaft für Gastroenterologie und Hepatologie
  • Medical University of Vienna

Zitieren

APA

Hintersteininger, M., Kappel, J., Müllner-Buscics, T., Riegler, S., Dominik, N., Kramer, G., Sebesta, C., Thöne, P., Stättermayer, A. F., Reider, L., Schoder, M., Klausenitz, C., Varga, R., Waneck, F., Trauner, M., Mandorfer, M., Reiberger, T., & Hartl, L. (2025). Effectiveness of controlled-expansion transjugular intrahepatic portosystemic shunt (CX-TIPS) in an interdisciplinary setting at a large tertiary center. Wiener klinische Wochenschrift. https://doi.org/10.1007/s00508-025-02606-7

Vancouver

Hintersteininger M, Kappel J, Müllner-Buscics T, Riegler S, Dominik N, Kramer G, et al. Effectiveness of controlled-expansion transjugular intrahepatic portosystemic shunt (CX-TIPS) in an interdisciplinary setting at a large tertiary center. Wiener klinische Wochenschrift. 2025. doi:10.1007/s00508-025-02606-7

BibTeX
@article{Hintersteininger2025,
  author = {Hintersteininger, Marlene and Kappel, Julia and Müllner-Buscics, Theresa and Riegler, Susanna and Dominik, Nina and Kramer, Georg and Sebesta, Christian and Thöne, Paul and Stättermayer, Albert Friedrich and Reider, Lukas and Schoder, Maria and Klausenitz, Catharina and Varga, Raoul and Waneck, Fredrik and Trauner, Michael and Mandorfer, Mattias and Reiberger, Thomas and Hartl, Lukas},
  title = {Effectiveness of controlled-expansion transjugular intrahepatic portosystemic shunt (CX-TIPS) in an interdisciplinary setting at a large tertiary center},
  journal = {Wiener klinische Wochenschrift},
  year = {2025},
  doi = {10.1007/s00508-025-02606-7}
}
Kostenlos starten →