EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

Incorporating an Elevated Perfusion Index in the Right Hand Enhanced Screening Sensitivity for Critical Aortic Arch Obstruction in Newborn Infants

Katarina Lannering iD, Ingegerd Östman-Smith iD, Mats Mellander iD

Acta Paediatrica · 2025

DOI: 10.1111/apa.17601 ↗

At a glance

Journal article in Acta Paediatrica, 2025. Written by Katarina Lannering and 2 co-authors. Institution: Department of Pediatric Cardiology, Queen Silvia Children's Hospital at the Sahlgrenska University Hospital, Gothenburg, Sweden. Major MEDLINE topics: Neonatal Screening, Perfusion Index, Hand, Aorta, Thoracic. Cited 2 times so far (Crossref); 19 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: ALF (Agreement between Swedish government and seven regions on clinical research), Hjärt-Lungfonden.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Aim

Newborn infants with critical aortic arch obstruction are often undiagnosed at discharge, despite screening. This study investigated if adding the perfusion index improved early detection.

Methods

We retrospectively studied 38 newborn infants with critical aortic arch obstruction, who were routinely screened in 2014–2019 by 13 Swedish hospitals using pulse oximetry and the perfusion index. They were identified through surgery records and national mortality databases. The controls were 512 healthy newborn infants from one hospital. Optimal perfusion index cut‐offs were determined using frequency distribution analysis.

Results

The groups had similar median gestational ages and birth weight. No infants with critical aortic arch obstruction were diagnosed just because of a positive perfusion index result. However, the right‐hand perfusion index was significantly higher in the cases than in controls ( p < 0.001). A perfusion index of > 3%, or positive pulse oximetry or positive physical examination, yielded 76% sensitivity and 85% specificity, with an area under the receiver operating characteristic curve of 0.81 (range 0.73–0.89, p < 0.0001). Pulse oximetry and just neonatal physical examinations had a lower sensitivity (45%, p = 0.009).

Conclusion

A high perfusion index in the right hand enhanced critical aortic arch obstruction screening and repeated measurements should be explored to minimise false positives.

Subjects

MeSH terms (MEDLINE)

Neonatal ScreeningPerfusion IndexHandAorta, ThoracicHumansInfant, NewbornRetrospective StudiesMaleFemaleOximetrySensitivity and Specificity

Author keywords

critical aortic coarctationearly detectionnewborn infantsperfusion indexpulse oximetry

Authors and institutions

  • Department of Pediatric Cardiology, Queen Silvia Children's Hospital at the Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Department of Pediatrics, Institution of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

ORCID profiles: Katarina Lannering, Ingegerd Östman-Smith, Mats Mellander

Funding

  • ALF (Agreement between Swedish government and seven regions on clinical research)
  • Hjärt-Lungfonden

Cite

APA

Lannering, K., Östman-Smith, I., & Mellander, M. (2025). Incorporating an Elevated Perfusion Index in the Right Hand Enhanced Screening Sensitivity for Critical Aortic Arch Obstruction in Newborn Infants. Acta Paediatrica. https://doi.org/10.1111/apa.17601

Vancouver

Lannering K, Östman-Smith I, Mellander M. Incorporating an Elevated Perfusion Index in the Right Hand Enhanced Screening Sensitivity for Critical Aortic Arch Obstruction in Newborn Infants. Acta Paediatrica. 2025. doi:10.1111/apa.17601

BibTeX
@article{Lannering2025,
  author = {Lannering, Katarina and Östman-Smith, Ingegerd and Mellander, Mats},
  title = {Incorporating an Elevated Perfusion Index in the Right Hand Enhanced Screening Sensitivity for Critical Aortic Arch Obstruction in Newborn Infants},
  journal = {Acta Paediatrica},
  year = {2025},
  doi = {10.1111/apa.17601}
}
Start for free →