EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of perfusion index on oxygen reserve index accuracy in estimating arterial oxygen tension in anesthetized dogs: Data reanalysis

Francesca Zanusso iD, Luca Bellini iD

PLOS ONE · 2025

DOI: 10.1371/journal.pone.0319823 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2025. Verfasst von Francesca Zanusso und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Animal Medicine, Production and Health, University of Padova, Legnaro, Italy. Hauptthemen laut MEDLINE: Oxygen, Perfusion Index. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Padova.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multi-wave CO-oximetry, utilizing the oxygen reserve index (ORi), estimates arterial partial pressure of oxygen (PaO 2 ) in mild hyperoxemia, between 100 and 200 mmHg, and concurrently quantifies local perfusion at the measurement site using the perfusion index (PI). This study explores how variations in PI influence the accuracy of ORi in estimating PaO 2 in anesthetized dogs. Data from 37 mechanically ventilated dogs were retrospectively reanalyzed using a different approach. ORi and PI values were collected using a CO-oximeter. The data were categorized into four groups based on PI quartiles. In each group, the relationship between ORi and PaO 2 was assessed using linear regression analysis, and the area under the receiver operating characteristic curve (AUROC) investigated the diagnostic performance of ORi in detecting PaO 2 > 150 mmHg. Strong relationships between ORi and PaO 2 were observed in groups with PI values < 2 (r 2 ≥ 0.63). The AUROC of ORi for identifying PaO 2 > 150 mmHg decreased with PI > 2 compared to lower values (0.76 vs > 0.88). In this study, PI values > 2 negatively impacted ORi’s ability to estimate PaO 2 , likely due to fluctuations in blood flow perfusing the measurement site. The results of this study suggests that consideration of the PI value is essential when titrating oxygen therapy using ORi in anesthetized dogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OxygenPerfusion IndexAnimalsDogsOximetryAnesthesiaRetrospective StudiesMaleFemaleRespiration, ArtificialROC Curve

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Animal Medicine, Production and Health, University of Padova, Legnaro, Italy.

ORCID-Profile: Francesca Zanusso, Luca Bellini

Förderung

  • Università degli Studi di Padova

Zitieren

APA

Zanusso, F., & Bellini, L. (2025). Effect of perfusion index on oxygen reserve index accuracy in estimating arterial oxygen tension in anesthetized dogs: Data reanalysis. PLOS ONE. https://doi.org/10.1371/journal.pone.0319823

Vancouver

Zanusso F, Bellini L. Effect of perfusion index on oxygen reserve index accuracy in estimating arterial oxygen tension in anesthetized dogs: Data reanalysis. PLOS ONE. 2025. doi:10.1371/journal.pone.0319823

BibTeX
@article{Zanusso2025,
  author = {Zanusso, Francesca and Bellini, Luca},
  title = {Effect of perfusion index on oxygen reserve index accuracy in estimating arterial oxygen tension in anesthetized dogs: Data reanalysis},
  journal = {PLOS ONE},
  year = {2025},
  doi = {10.1371/journal.pone.0319823}
}
Kostenlos starten →