Accuracy of 12 IOL power calculation formulas in highly myopic eyes
International Ophthalmology · 2025
DOI: 10.1007/s10792-025-03608-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Ophthalmology, 2025. Verfasst von Magí Vilaltella und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine and Surgery, Faculty of Medicine, University of Lleida, Carrer de Montserrat Roig, 2, 25008, Lleida, Spain. magi.vilaltella@ud…. Hauptthemen laut MEDLINE: Lenses, Intraocular, Optics and Photonics, Refraction, Ocular, Biometry. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitat de Lleida.
Abstract (Originalsprache)
Purpose
To assess and compare the accuracy of 12 intraocular lens (IOL) power calculation formulas after cataract phacoemulsification surgery in eyes with an axial length (AL) greater than or equal to 26.00 mm (≥ 26.00 mm).
Methods
A retrospective case series study including 72 eyes with an AL ≥ 26.00 mm that underwent uneventful cataract surgery. Twelve IOL power calculation formulas were evaluated: SRK/T, Holladay 1, Haigis, Holladay 2, Barrett Universal II, Kane, EVO, Pearl-DGS, Hill RBF 3.0, SRK/T and Holladay 1 with the modified W-K AL adjustment, and Holladay 2 with the non-linear W-K AL adjustment. The median absolute error (MedAE), mean absolute error (MAE) and the percentage of eyes within specific prediction error thresholds were calculated and compared across formulas after adjusting the mean error to zero.
Results
Holladay 1 modified W-K obtained the lowest MedAE (0.215 DP), followed by Kane (0.233 DP), Barrett (0.246 DP), Pearl and EVO (0.252 DP). Barrett, Kane and EVO yielded significantly lower MedAEs compared to SRK/T ( p < 0.05); and Holladay 1 modified W-K yielded significantly lower MedAEs compared to SRK/T modified W-K ( p < 0.05). Holladay 1 modified W-K achieved the lowest MAE (0.314 DP), followed very closely by Barrett (0.317 DP), and subsequently by Pearl (0.324 DP), Kane (0.329 DP) and EVO (0.331 DP).
Conclusion
Our study reflects a superior accuracy of the Holladay 1 modified W-K formula, along with the Kane, Barrett, EVO and Pearl-DGS formulas in predicting refractive outcomes for eyes with an AL greater than 26.00 mm undergoing cataract phacoemulsification surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medicine and Surgery, Faculty of Medicine, University of Lleida, Carrer de Montserrat Roig, 2, 25008, Lleida, Spain. magi.vilaltella@udl.cat.
- Department of Ophthalmology, University Hospital Arnau de Vilanova, Lleida, Spain. magi.vilaltella@udl.cat.
- Department of Ophthalmology, University Hospital Arnau de Vilanova, Lleida, Spain.
- Department of Endocrinology and Nutrition, Centro Médico Milenium, Saragossa, Spain.
- Department of Medicine and Surgery, Faculty of Medicine, University of Lleida, Carrer de Montserrat Roig, 2, 25008, Lleida, Spain.
Förderung
- Universitat de Lleida
Zitieren
APA
Vilaltella, M., Cid-Bertomeu, P., Serés-Noriega, T., & Huerva, V. (2025). Accuracy of 12 IOL power calculation formulas in highly myopic eyes. International Ophthalmology. https://doi.org/10.1007/s10792-025-03608-0
Vancouver
Vilaltella M, Cid-Bertomeu P, Serés-Noriega T, Huerva V. Accuracy of 12 IOL power calculation formulas in highly myopic eyes. International Ophthalmology. 2025. doi:10.1007/s10792-025-03608-0
BibTeX
@article{Vilaltella2025,
author = {Vilaltella, Magí and Cid-Bertomeu, Pau and Serés-Noriega, Tonet and Huerva, Valentín},
title = {Accuracy of 12 IOL power calculation formulas in highly myopic eyes},
journal = {International Ophthalmology},
year = {2025},
doi = {10.1007/s10792-025-03608-0}
}
EUVIMED