Journal article in Artificial Organs, 2025. Written by Sara S Inglis and 8 co-authors. Institution: Deparment of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA. Major MEDLINE topics: Heart-Assist Devices, Hemodynamics, Heart Failure, Exercise. Cited 1 times so far (Crossref); 22 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Addition of left heart catheterization (LHC) to exercise protocols allows for a unique focus on parameters of systolic and diastolic responses to increased activity in patients with left ventricular assist device (LVAD) support.

Methods

A retrospective review was conducted of all consecutive adult patients who underwent LHC with exercise for any indication from June 2017 to June 2023. For all patients, the relationship between exercise and parameters of LV systolic and diastolic response was assessed. Patients were divided into two cohorts based on the indication for testing: hemodynamic optimization (Optim, n = 5) or weaning consideration (Wean, n = 3).

Results

Eight patients (88% male, median age 57 years (IQR 44, 65)) were included. LVEF was 45% (IQR 45, 56) in Wean and 25% (IQR 20, 42) in Optim. LV systolic work index (LVSWI) increased more rapidly over levels of exercise in Wean vs. Optim (slope 46.3 vs. −0.625; p = 0.044) and LVSWI rose more quickly at lower levels of LV end diastolic pressure (LVEDP) in Wean vs. Optim (slope 219.5 vs. −2.008; p = 0.0026). Pulse power index was higher in Wean patients at baseline (0.046 (IQR 0.04, 0.07) vs. 0.016 (IQR 0.001, 0.04); p = 0.14) and peak exercise (0.12 (IQR 0.12, 0.12) vs. 0.06 (IQR 0.03, 0.1); p = 0.29).

Conclusions

Patients with favorable remodeling on LVAD support have significantly improved LV systolic and diastolic responses to exercise and a trend of higher systemic pulsatility. Improving our understanding of LV‐LVAD interactions with activity may aid in future efforts to improve exercise tolerance through speed modulation.

Subjects

MeSH terms (MEDLINE)

Heart-Assist DevicesHemodynamicsHeart FailureExerciseVentricular Function, LeftHumansMaleMiddle AgedFemaleRetrospective StudiesAgedAdultCardiac Catheterization

Author keywords

exercisehemodynamicsleft heart catheterizationleft ventricular assist device

Authors and institutions

  • Deparment of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.
  • Van Cleve Cardiac Regenerative Medicine Program, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA.

ORCID profiles: Sara S Inglis, Sarah D Schettle, Andrew N Rosenbaum

Cite

APA

Inglis, S. S., Schettle, S. D., Villavicencio, M. A., Spencer, P. J., Stulak, J. M., Tang, P. C., Kushwaha, S. S., Behfar, A., & Rosenbaum, A. N. (2025). Assessment of Left‐Sided Hemodynamics With Exercise in Patients With Continuous Flow Left Ventricular Assist Device Support. Artificial Organs. https://doi.org/10.1111/aor.14995

Vancouver

Inglis SS, Schettle SD, Villavicencio MA, Spencer PJ, Stulak JM, Tang PC, et al. Assessment of Left‐Sided Hemodynamics With Exercise in Patients With Continuous Flow Left Ventricular Assist Device Support. Artificial Organs. 2025. doi:10.1111/aor.14995

BibTeX
@article{Inglis2025,
  author = {Inglis, Sara S and Schettle, Sarah D and Villavicencio, Mauricio A and Spencer, Philip J and Stulak, John M and Tang, Paul C and Kushwaha, Sudhir S and Behfar, Atta and Rosenbaum, Andrew N},
  title = {Assessment of Left‐Sided Hemodynamics With Exercise in Patients With Continuous Flow Left Ventricular Assist Device Support},
  journal = {Artificial Organs},
  year = {2025},
  doi = {10.1111/aor.14995}
}
Start for free →