EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Ultrasound Assessment of Venous and Pulmonary Congestion in Left Ventricular Assist Devices Patients

Attilio Iacovoni iD, Cinzia Giaccherini, Sara Paris, Raffaele Abete, Claudia Vittori, Riccardo Maria Inciardi, Ottavio Zucchetti iD, Amedeo Terzi, Michele Senni

Artificial Organs · 2025

DOI: 10.1111/aor.14985 ↗

At a glance

Journal article in Artificial Organs, 2025. Written by Attilio Iacovoni and 8 co-authors. Institution: Cardiovascular Department, Azienda Socio Sanitaria Territoriale Papa Giovanni XXIII, Bergamo, Italy. Major MEDLINE topics: Heart-Assist Devices, Heart Failure, Lung, Pulmonary Edema. Cited 2 times so far (Crossref); 30 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

A significant number of (left ventricular assist device) LVAD patients (pts) have hemodynamic‐related adverse events requiring right heart catheterization (RHC). Venous and lung ultrasound is an established method for evaluating congestion in heart failure pts. This study aimed to investigate the role of these ultrasound parameters in the hemodynamic assessment of LVAD pts.

Methods

RHC and complete echocardiography were performed on 50 consecutive LVAD pts, 12 of whom were the validation cohort. Pts were stratified based on right atrial pressure (RAP) ≥ 7 mmHg and pulmonary capillary wedge pressure (PCWP) > 15 mmHg.

Results

The median LVAD follow‐up time was 400 (209–900) days. Baseline characteristics were similar between high vs. normal RAP groups, except for NYHA class and renal function in the former group. High vs. normal PCWP showed a greater NYHA class and a furosemide dose. All hemodynamic parameters were significantly different in the high RAP group except for cardiac output (CO) and cardiac index (CI). In contrast, in the high PCWP group, no differences in CO, CI, and pulmonary vascular resistances were apparent. The most accurate non‐invasive variable for detecting high RAP was renal venous stasis index (RVSI), receiver‐operating characteristic curves for areas under the curve (AUC), 0.78 (95% CI, 0.62–0.93). Estimated left atrial pressure (LAP‐eRAP) was the most accurate non‐invasive value to discriminate high PCWP (AUC 0.85 95% CI 0.73–0.98).

Conclusion

This study found a good correlation between RAP, PWCP, and non‐invasive parameters, such as RVSI and LAP‐eRAP, suggesting the importance of peripheral venous ultrasound in LVAD patients.

Subjects

MeSH terms (MEDLINE)

Heart-Assist DevicesHeart FailureLungPulmonary EdemaHumansMaleFemaleMiddle AgedEchocardiographyAgedHemodynamicsAdultPulmonary Wedge PressureUltrasonographyCardiac CatheterizationAtrial Pressure

Author keywords

Doppler vein signalsPOCUSechocardiographyleft ventricular assisted device

Authors and institutions

  • Cardiovascular Department, Azienda Socio Sanitaria Territoriale Papa Giovanni XXIII, Bergamo, Italy.
  • FROM Research Foundation E.T.S., Papa Giovanni XXIII Hospital, Bergamo, Italy.
  • Institute of Cardiology, ASST Spedali Civili di Brescia, Brescia, Italy.
  • Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy.

ORCID profiles: Attilio Iacovoni, Ottavio Zucchetti

Cite

APA

Iacovoni, A., Giaccherini, C., Paris, S., Abete, R., Vittori, C., Inciardi, R. M., Zucchetti, O., Terzi, A., & Senni, M. (2025). Ultrasound Assessment of Venous and Pulmonary Congestion in Left Ventricular Assist Devices Patients. Artificial Organs. https://doi.org/10.1111/aor.14985

Vancouver

Iacovoni A, Giaccherini C, Paris S, Abete R, Vittori C, Inciardi RM, et al. Ultrasound Assessment of Venous and Pulmonary Congestion in Left Ventricular Assist Devices Patients. Artificial Organs. 2025. doi:10.1111/aor.14985

BibTeX
@article{Iacovoni2025,
  author = {Iacovoni, Attilio and Giaccherini, Cinzia and Paris, Sara and Abete, Raffaele and Vittori, Claudia and Inciardi, Riccardo Maria and Zucchetti, Ottavio and Terzi, Amedeo and Senni, Michele},
  title = {Ultrasound Assessment of Venous and Pulmonary Congestion in Left Ventricular Assist Devices Patients},
  journal = {Artificial Organs},
  year = {2025},
  doi = {10.1111/aor.14985}
}
Start for free →