EUVIMEDEUVIMED entdecken
Crossref

Predictive Value of Noninvasive Right Ventricular to Pulmonary Artery Uncoupling for Right Ventricular Failure After Left Ventricular Assist Device Implantation

Kayo Misumi, Toru Hashimoto, Takeo Fujino, Gentaro Taniguchi, Kei Ikuta, Tomoaki Yoshitake, Shoei Yamamoto, Keisuke Shinohara, Shouji Matsushima, Tomoki Ushijima, Hiromichi Sonoda, Akira Shiose und 1 weitere

Circulation Journal · 2026

DOI: 10.1253/circj.cj-25-0743 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation Journal, 2026. Verfasst von Kayo Misumi und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Faculty of Medical Sciences, Kyushu University. Hauptthemen laut MEDLINE: Heart-Assist Devices, Pulmonary Artery, Heart Failure, Ventricular Dysfunction, Right. Die Arbeit nennt 43 Literaturangaben. Gefördert von: Fukuda Foundation for Medical Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Although early right ventricular failure (eRVF) following durable left ventricular assist device (dLVAD) implantation is associated with a poor prognosis, reliable predictive parameters have not yet been established. In this study we evaluated the predictive value of right ventricular (RV) to pulmonary artery (PA) uncoupling, measured by the ratio of tricuspid annular plane systolic excursion (TAPSE) to PA systolic pressure (PASP), in patients undergoing dLVAD implantation. METHODS AND RESULTS: We conducted a single-center retrospective study of adult patients who underwent dLVAD implantation between January 2008 and December 2024. eRVF was defined as receiving short- or long-term right-sided circulatory support, or continuous inotropic support for more than 14 days within 30 days after dLVAD implantation. Preoperative echocardiographic variables, including the TAPSE/PASP ratio and right-sided heart catheter parameters, were analyzed using univariate and multivariate logistic regression models to identify eRVF predictors. We analyzed data for 111 patients who underwent dLVAD implantation and 46.8% developed eRVF postoperatively. The TAPSE/PASP ratio was an independent predictor of eRVF, even after adjustments for other echocardiographic variables (odds ratio [OR], 0.05; 95% confidence interval [CI], 0.004-0.67, P=0.024) and right-sided heart catheter variables (OR, 0.04; 95% CI, 0.002-0.69, P=0.027). CONCLUSIONS: Preoperative RV-PA uncoupling, assessed using the TAPSE/PASP ratio, may predict eRVF following dLVAD implantation. This parameter is clinically accessible and valuable for preoperative risk stratification and may facilitate improved perioperative management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesPulmonary ArteryHeart FailureVentricular Dysfunction, RightVentricular Function, RightHumansRetrospective StudiesFemaleMiddle AgedMalePredictive Value of TestsEchocardiographyAgedAdult

Stichwörter der Autor:innen

Left ventricular assist devices (LVAD)Right ventricular failureTricuspid annular plane systolic excursion (TAPSE)

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Faculty of Medical Sciences, Kyushu University.
  • Department of Advanced Cardiopulmonary Failure, Faculty of Medical Sciences, Kyushu University.
  • Department of Cardiovascular Surgery, Faculty of Medical Sciences, Kyushu University.

Förderung

  • Fukuda Foundation for Medical Technology

Zitieren

APA

Misumi, K., Hashimoto, T., Fujino, T., Taniguchi, G., Ikuta, K., Yoshitake, T., Yamamoto, S., Shinohara, K., Matsushima, S., Ushijima, T., Sonoda, H., Shiose, A., & Abe, K. (2026). Predictive Value of Noninvasive Right Ventricular to Pulmonary Artery Uncoupling for Right Ventricular Failure After Left Ventricular Assist Device Implantation. Circulation Journal. https://doi.org/10.1253/circj.cj-25-0743

Vancouver

Misumi K, Hashimoto T, Fujino T, Taniguchi G, Ikuta K, Yoshitake T, et al. Predictive Value of Noninvasive Right Ventricular to Pulmonary Artery Uncoupling for Right Ventricular Failure After Left Ventricular Assist Device Implantation. Circulation Journal. 2026. doi:10.1253/circj.cj-25-0743

BibTeX
@article{Misumi2026,
  author = {Misumi, Kayo and Hashimoto, Toru and Fujino, Takeo and Taniguchi, Gentaro and Ikuta, Kei and Yoshitake, Tomoaki and Yamamoto, Shoei and Shinohara, Keisuke and Matsushima, Shouji and Ushijima, Tomoki and Sonoda, Hiromichi and Shiose, Akira and Abe, Kohtaro},
  title = {Predictive Value of Noninvasive Right Ventricular to Pulmonary Artery Uncoupling for Right Ventricular Failure After Left Ventricular Assist Device Implantation},
  journal = {Circulation Journal},
  year = {2026},
  doi = {10.1253/circj.cj-25-0743}
}
Kostenlos starten →