Continuous Blood Gas Control Based on Active Disturbance Rejection Control During Ex Vivo Porcine Liver Perfusion

Yilong Zhao iD, Xin Lyu, Zhen Sun, Xiaoliang Zhang, Jin Cen, Tianhang Yang, Xiaoliang Xu, Wenhui Xing, Sihan Zhao, Bidou Wang, Gangyin Luo iD

Artificial Organs · 2025

DOI: 10.1111/aor.14955 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2025. Verfasst von Yilong Zhao und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, Hefei, China. Hauptthemen laut MEDLINE: Liver, Perfusion, Oxygen, Organ Preservation. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Strategic Priority Research Program of the Chinese Academy of Sciences, Key Technology (Research) Project of Prevention and Control of Major Diseases and Infectious Diseases of Suzhou, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Membrane oxygenators facilitate extracorporeal gas exchange, necessitating the monitoring of blood gas. Recent advances in normothermic machine perfusion (NMP) for ex vivo liver offer solutions to the shortage of donor liver. However, maintaining physiological blood gas levels during prolonged NMP is complex and costly.

Methods

We introduce a noninvasive and economical approach for regulating the blood gas during NMP of ex vivo porcine livers. By monitoring gas fractions at the outlet of oxygenator, real‐time adjustments of blood gas can be made without the online blood gas analyzer. The method involves constructing multivariate linear regression (MLR) models, aligning target setpoints of gas, and employing active disturbance rejection control (ADRC) to achieve closed‐loop regulation.

Results

Ex vivo porcine liver perfusion experiments demonstrated the effectiveness of the method, maintaining blood gas within physiological levels over 24 h (oxygen partial pressure: 150.36 ± 3.33 mmHg, carbon dioxide partial pressure: 41.34 ± 0.91 mmHg).

Conclusion

ADRC‐based continuous regulation of gas fraction at the outlet of oxygenator is a feasible and effective approach for managing blood gas during ex vivo porcine liver perfusion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverPerfusionOxygenOrgan PreservationAnimalsSwineBlood Gas AnalysisLiver TransplantationCarbon DioxideOxygenators, Membrane

Stichwörter der Autor:innen

ADRCMLRNMPblood gas controlmembrane oxygenator

Substanzen

OxygenCarbon Dioxide

Autor:innen und Institutionen

  • School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, Hefei, China.
  • Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China.
  • State Key Laboratory of Cell Biology, Center for Excellence in Molecular Cell Science, Shanghai Institute of Biochemistry and Cell Biology, Chinese Academy of Sciences, University of Chinese Academy of Sciences, Shangha…
  • Hainan Academy of Medical Sciences, Hainan Medical University, Haikou, Hainan, China.

ORCID-Profile: Yilong Zhao, Gangyin Luo

Förderung

  • Strategic Priority Research Program of the Chinese Academy of Sciences
  • Key Technology (Research) Project of Prevention and Control of Major Diseases and Infectious Diseases of Suzhou, China

Zitieren

APA

Zhao, Y., Lyu, X., Sun, Z., Zhang, X., Cen, J., Yang, T., Xu, X., Xing, W., Zhao, S., Wang, B., & Luo, G. (2025). Continuous Blood Gas Control Based on Active Disturbance Rejection Control During Ex Vivo Porcine Liver Perfusion. Artificial Organs. https://doi.org/10.1111/aor.14955

Vancouver

Zhao Y, Lyu X, Sun Z, Zhang X, Cen J, Yang T, et al. Continuous Blood Gas Control Based on Active Disturbance Rejection Control During Ex Vivo Porcine Liver Perfusion. Artificial Organs. 2025. doi:10.1111/aor.14955

BibTeX
@article{Zhao2025,
  author = {Zhao, Yilong and Lyu, Xin and Sun, Zhen and Zhang, Xiaoliang and Cen, Jin and Yang, Tianhang and Xu, Xiaoliang and Xing, Wenhui and Zhao, Sihan and Wang, Bidou and Luo, Gangyin},
  title = {Continuous Blood Gas Control Based on Active Disturbance Rejection Control During Ex Vivo Porcine Liver Perfusion},
  journal = {Artificial Organs},
  year = {2025},
  doi = {10.1111/aor.14955}
}
Kostenlos starten →