EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Longitudinal cardiac dimensions in patients undergoing LVAD implantation

Florian Meissner iD, Sophie Szvetics, Michelle Costa Galbas, Maximilian Russe, David Schibilsky iD, Klaus Kaier, Martin Czerny, Wolfgang Bothe

Artificial Organs · 2024

DOI: 10.1111/aor.14728 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2024. Verfasst von Florian Meissner und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Heart Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany. Hauptthemen laut MEDLINE: Thoracic Surgical Procedures, Heart-Assist Devices, Heart Failure. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: German Federal Ministry of Education and Research, Bundesministerium für Bildung und Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In conventional left ventricular assist devices (LVAD), a separate outflow graft is sutured to the ascending aorta. Novel device designs may include a transventricular outflow cannula crossing the aortic valve (AV). While transversal ventricular dimensions are well investigated in patients with severe heart failure, little is known about the longitudinal dimensions. These dimensions are, however, particularly critical for the design and development of mechanical circulatory support (MCS) devices with transaortic outflow cannula.

Methods

In an explorative retrospective cohort study at the University Medical Center Freiburg, Germany, the longitudinal cardiac dimensions of patients undergoing computed tomography angiography (CTA) before and, if available, after LVAD implantation were analyzed. Among others, the following dimensions were assessed: (a) apex to AV, (b) apex to mitral valve, (c) AV to sinotubular junction (STJ), (d) apex to STJ, (e) apex to brachiocephalic artery (BCA), and (f) AV to BCA.

Results

In total, 44 LVAD patients (36 male, age 55.8 years, height 1.75 m) were included. The longitudinal cardiac dimensions were (a) 114.5 ± 12.1 mm, (b) 108.0 ± 12.4 mm, (c) 20.9 ± 2.9, (d) 135.4 ± 13.4 mm, (e) 206.0 ± 18.3, and (f) 91.5 ± 9.8 mm. Postoperatively, (a) and (b) decreased by 31.5% and 39.5%, respectively ( N = 14).

Conclusions

Longitudinal cardiac dimensions may be reduced by up to 40% after LVAD implantation. A better knowledge of these dimensions and their postoperative alterations in LVAD patients may improve surgical planning and help to design MCS devices with transventricular outflow cannula.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thoracic Surgical ProceduresHeart-Assist DevicesHeart FailureHumansMaleMiddle AgedRetrospective StudiesAorta, ThoracicAortaAortic ValveTreatment Outcome

Stichwörter der Autor:innen

computed tomography angiographyheart failureleft ventricular assist devicelongitudinal cardiac dimensionsmechanical circulatory supportreverse cardiac remodeling

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Heart Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Institute of Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

ORCID-Profile: Florian Meissner, David Schibilsky

Förderung

  • German Federal Ministry of Education and Research
  • Bundesministerium für Bildung und Forschung

Zitieren

APA

Meissner, F., Szvetics, S., Galbas, M. C., Russe, M., Schibilsky, D., Kaier, K., Czerny, M., & Bothe, W. (2024). Longitudinal cardiac dimensions in patients undergoing LVAD implantation. Artificial Organs. https://doi.org/10.1111/aor.14728

Vancouver

Meissner F, Szvetics S, Galbas MC, Russe M, Schibilsky D, Kaier K, et al. Longitudinal cardiac dimensions in patients undergoing LVAD implantation. Artificial Organs. 2024. doi:10.1111/aor.14728

BibTeX
@article{Meissner2024,
  author = {Meissner, Florian and Szvetics, Sophie and Galbas, Michelle Costa and Russe, Maximilian and Schibilsky, David and Kaier, Klaus and Czerny, Martin and Bothe, Wolfgang},
  title = {Longitudinal cardiac dimensions in patients undergoing LVAD implantation},
  journal = {Artificial Organs},
  year = {2024},
  doi = {10.1111/aor.14728}
}
Kostenlos starten →