EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On the necessity to include arterial pre-stress in patient-specific simulations of minimally invasive procedures

Anna Ramella, Vittorio Lissoni, Sara Bridio, Jose Felix Rodriguez Matas, Santi Trimarchi, Benedetta Grossi, Giulio G Stefanini, Francesco Migliavacca, Giulia Luraghi

Biomechanics and Modeling in Mechanobiology · 2024-04 · 23 (2) · 525-537

DOI: 10.1007/s10237-023-01789-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomechanics and Modeling in Mechanobiology, online erschienen am 08.12.2023. Verfasst von Anna Ramella und 8 weiteren Autor:innen. Beteiligte Einrichtung: Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piaz…. Hauptthemen laut MEDLINE: Endovascular Procedures, Transcatheter Aortic Valve Replacement, Aortic Aneurysm, Thoracic. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero dell'Istruzione, dell'Università e della Ricerca, European Union - NextGenerationEU, Ministero dell’Istruzione, dell’Università e della Ricerca.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcatheter aortic valve implantation (TAVI) and thoracic endovascular aortic repair (TEVAR) are minimally invasive procedures for treating aortic valves and diseases. Finite element simulations have proven to be valuable tools in predicting device-related complications. In the literature, the inclusion of aortic pre-stress has not been widely investigated. It plays a crucial role in determining the biomechanical response of the vessel and the device–tissue interaction. This study aims at demonstrating how and when to include the aortic pre-stress in patient-specific TAVI and TEVAR simulations. A percutaneous aortic valve and a stent-graft were implanted in aortic models reconstructed from patient-specific CT scans. Two scenarios for each patient were compared, i.e., including and neglecting the wall pre-stress. The neglection of pre-stress underestimates the contact pressure of 48% and 55%, the aorta stresses of 162% and 157%, the aorta strains of 77% and 21% for TAVI and TEVAR models, respectively. The stent stresses are higher than 48% with the pre-stressed aorta in TAVI simulations; while, similar results are obtained in TEVAR cases. The distance between the device and the aorta is similar with and without pre-stress. The inclusion of the aortic wall pre-stress has the capability to give a better representation of the biomechanical behavior of the arterial tissues and the implanted device. It is suggested to include this effect in patient-specific simulations replicating the procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endovascular ProceduresTranscatheter Aortic Valve ReplacementAortic Aneurysm, ThoracicHumansAortic ValveStentsAortaTreatment OutcomeAorta, ThoracicBlood Vessel Prosthesis

Stichwörter der Autor:innen

Aortic valveFinite element analysisStent-graftThoracic endovascular aortic repairTranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy.
  • Section of Vascular Surgery, Cardio Thoracic Vascular Department, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 35, Milan, Italy.
  • Department of Clinical Sciences and Community Health, University of Milan, Via Della Commenda 19, 20122, Milan, Italy.
  • Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy.
  • IRCCS Humanitas Research Hospital, Via Alessandro Manzoni 56, 20089, Rozzano, Milan, Italy.
  • Computational Biomechanics Laboratory - LaBS, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Piazza L. da Vinci 32, 20133, Milan, Italy. giulia.luraghi@polimi.it.

Förderung

  • Ministero dell'Istruzione, dell'Università e della Ricerca
  • European Union - NextGenerationEU
  • Ministero dell’Istruzione, dell’Università e della Ricerca
  • European Union – NextGenerationEU
  • Politecnico di Milano

Zitieren

APA

Ramella, A., Lissoni, V., Bridio, S., Rodriguez Matas, J. F., Trimarchi, S., Grossi, B., Stefanini, G. G., Migliavacca, F., & Luraghi, G. (2024). On the necessity to include arterial pre-stress in patient-specific simulations of minimally invasive procedures. Biomechanics and Modeling in Mechanobiology, 23(2), 525-537. https://doi.org/10.1007/s10237-023-01789-0

Vancouver

Ramella A, Lissoni V, Bridio S, Rodriguez Matas JF, Trimarchi S, Grossi B, et al. On the necessity to include arterial pre-stress in patient-specific simulations of minimally invasive procedures. Biomechanics and Modeling in Mechanobiology. 2024;23(2):525-537. doi:10.1007/s10237-023-01789-0

BibTeX
@article{Ramella2024,
  author = {Ramella, Anna and Lissoni, Vittorio and Bridio, Sara and Rodriguez Matas, Jose Felix and Trimarchi, Santi and Grossi, Benedetta and Stefanini, Giulio G and Migliavacca, Francesco and Luraghi, Giulia},
  title = {On the necessity to include arterial pre-stress in patient-specific simulations of minimally invasive procedures},
  journal = {Biomechanics and Modeling in Mechanobiology},
  year = {2024},
  volume = {23},
  number = {2},
  pages = {525--537},
  doi = {10.1007/s10237-023-01789-0}
}