Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed‐wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study
Acta Obstetricia et Gynecologica Scandinavica · 2026
DOI: 10.1111/aogs.70340 ↗At a glance
Journal article in Acta Obstetricia et Gynecologica Scandinavica, 2026. Written by Juulia Lantto and 6 co-authors. Institution: Division of Obstetrics & Gynecology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden. Major MEDLINE topics: Fetal Heart, Heart Rate, Fetal, Ultrasonography, Prenatal, Echocardiography, Doppler, Pulsed. 52 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Introduction
This study evaluated agreement between automated analysis of color tissue Doppler (cTDI) cine loops and manual spectral pulsed‐wave tissue Doppler (pwTDI) measurements of fetal cardiac cycle time intervals and myocardial velocities under normal and pathological conditions in an experimental model using fetal sheep. Material and Methods In 10 sheep fetuses, 25%–50% partial ascending aorta constriction was performed, and in nine, utero‐placental blood flow was reduced by maternal uterine artery occlusion. Four fetuses served as controls. Experiments were performed after 4 to 5 days recovery, and cTDI cine loops and pwTDI waveforms were sequentially obtained during baseline and during fetal hypoxemia induced by maternal hypo‐oxygenation. cTDI cine loops were processed using an automated, ECG‐independent algorithm, whereas pwTDI waveforms were manually traced to measure cardiac cycle time intervals and myocardial velocities.
Results
Fetal heart rate (FHR) showed excellent agreement between methods (intraclass correlation coefficient, ICC = 0.94). In contrast, myocardial velocities and cardiac time intervals demonstrated poor‐to‐moderate absolute agreement (ICC range 0.20–0.63). Bland–Altman analysis revealed systematic modality‐specific offsets: the automated method yielded consistently lower velocities and longer isovolumic intervals. These offsets were stable across physiological states, with no metric showing phase‐dependent changes in bias after Benjamini–Hochberg false discovery rate (FDR) correction (all q > 0.05). Despite limited absolute agreement, consistency and correlation (ICC(C,1) and Pearson r) were markedly higher than absolute agreement, indicating strong preservation of relative ranking across methods. Lin's concordance correlation coefficient (CCC) showed a similar pattern, with high concordance for FHR (CCC = 0.936) and lower concordance for most other metrics.
Conclusions
Automated cTDI is not directly interchangeable with manual pwTDI for absolute measurements of sheep fetal myocardial velocities or time intervals due to persistent modality‐specific offsets. However, the automated method provides reproducible relative tracking and stable performance across different physiological conditions. Automated cTDI is therefore well suited for longitudinal assessments when interpreted using method‐specific baselines or calibration. FHR was the only parameter demonstrating near‐interchangeable performance.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Division of Obstetrics & Gynecology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden.
- Centre for Fetal Medicine, Karolinska University Hospital, Stockholm, Sweden.
- Translational Research Group, Oulu University Hospital and Oulu University, Oulu, Finland.
- St. George's Hospital and City-St. George's, University of London, London, UK.
- Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
ORCID profiles: Juulia Lantto, Ganesh Acharya
Cite
APA
Lantto, J., Morena, M. G., Huhta, H., Bhide, A., Johnson, J., Räsänen, J., & Acharya, G. (2026). Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed‐wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.70340
Vancouver
Lantto J, Morena MG, Huhta H, Bhide A, Johnson J, Räsänen J, et al. Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed‐wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study. Acta Obstetricia et Gynecologica Scandinavica. 2026. doi:10.1111/aogs.70340
BibTeX
@article{Lantto2026,
author = {Lantto, Juulia and Morena, Maria Grazia and Huhta, Heikki and Bhide, Amar and Johnson, Jonas and Räsänen, Juha and Acharya, Ganesh},
title = {Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed‐wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study},
journal = {Acta Obstetricia et Gynecologica Scandinavica},
year = {2026},
doi = {10.1111/aogs.70340}
}
EUVIMED