Impact of pulsed Doppler sample volume position on fetal cardiac output calculation
Journal of Medical Ultrasonics · 2026
DOI: 10.1007/s10396-026-01619-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Ultrasonics, 2026. Verfasst von Kosuke Yonehara und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Nagano Children's Hospital, Azumino, Nagano, 399-8288, Japan. kosuke-yonehara@nkodomo-hsp.jp. Hauptthemen laut MEDLINE: Cardiac Output, Ultrasonography, Prenatal, Echocardiography, Doppler, Pulsed, Fetal Heart. Die Arbeit nennt 7 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This study aimed to evaluate the impact of sample volume position on fetal cardiac output (CO) measurements. METHODS: Fetuses with normal hearts were enrolled. Fetal CO was calculated using the pulsed Doppler method, with the velocity time integral (VTI) recorded at two distinct positions: the valve hinge level (Valve: V group) and just distal to the valve (Supra-valve: S group). Additionally, we acquired electronic spatio-temporal image correlation (eSTIC) volume data. Left-ventricular CO was calculated as the product of stroke volume and heart rate, with stroke volume derived from left-ventricular volume measurements using the virtual organ computer-aided analysis (VOCAL) technique on the three-dimensional eSTIC data (eSTIC group). We then compared the left-ventricular CO levels among the V, S, and eSTIC groups to assess their correlation. RESULTS: The S group showed significantly larger VTI of the aortic valve (8.5 ± 2.3 vs. 9.3 ± 2.5 cm, V vs. S group). Similarly, the S group also had significantly larger VTI of the pulmonary valve (7.0 ± 1.9 vs. 8.2 ± 2.2 cm). Combined cardiac output (CCO) in the V group was 396 ± 136 mL/min/kg, and that in the S group was 450 ± 154 mL/kg/min, which also showed that the S group had a significantly larger CCO. Focusing on left ventricle CO, the V group was 140 ± 73 mL/kg/min, the S group was 157 ± 77 mL/kg/min, and the eSTIC group was 133 ± 69 mL/kg/min. This suggested that the V group's results were more similar to the eSTIC group's. CONCLUSION: This study suggests that CO measurements are significantly influenced by the sample volume position. Furthermore, placing the VTI sample volume on the valve hinge level appears to reflect CO more accurately.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiology, Nagano Children's Hospital, Azumino, Nagano, 399-8288, Japan. kosuke-yonehara@nkodomo-hsp.jp.
- Department of Pediatric Cardiology, Nagano Children's Hospital, Azumino, Nagano, 399-8288, Japan.
- Department of Pediatrics, Tottori Prefectural Central Hospital, Tottori, Tottori, Japan.
Zitieren
APA
Yonehara, K., Takigiku, K., Tanaka, N., Numata, R., Shibuya, Y., Obinata, H., Akazawa, Y., & Takei, K. (2026). Impact of pulsed Doppler sample volume position on fetal cardiac output calculation. Journal of Medical Ultrasonics. https://doi.org/10.1007/s10396-026-01619-7
Vancouver
Yonehara K, Takigiku K, Tanaka N, Numata R, Shibuya Y, Obinata H, et al. Impact of pulsed Doppler sample volume position on fetal cardiac output calculation. Journal of Medical Ultrasonics. 2026. doi:10.1007/s10396-026-01619-7
BibTeX
@article{Yonehara2026,
author = {Yonehara, Kosuke and Takigiku, Kiyohiro and Tanaka, Noboru and Numata, Ryusuke and Shibuya, Yuma and Obinata, Haruka and Akazawa, Yohei and Takei, Kohta},
title = {Impact of pulsed Doppler sample volume position on fetal cardiac output calculation},
journal = {Journal of Medical Ultrasonics},
year = {2026},
doi = {10.1007/s10396-026-01619-7}
}
EUVIMED