To guide or not to guide: A randomized study on the use of needle guide for chorionic villus sampling training
Acta Obstetricia et Gynecologica Scandinavica · 2026
DOI: 10.1111/aogs.70108 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Acta Obstetricia et Gynecologica Scandinavica, 2026. Verfasst von Vilma Johnsson und 8 weiteren Autor:innen. Beteiligte Einrichtung: Copenhagen Academy for Medical Education and Simulation (CAMES), Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Chorionic Villi Sampling, Clinical Competence, Ultrasonography, Interventional, Obstetrics. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: AMEE, NoVo Foundation.
Abstract (Originalsprache)
Introduction
Chorionic villus sampling (CVS) is an invasive prenatal diagnostic procedure used to detect fetal genetic anomalies. CVS is increasingly replaced by noninvasive prenatal testing (NIPT). As a consequence, maintaining procedural skills among trainees has become challenging. Despite this, optimal training methods for CVS remain uncertain, particularly regarding whether techniques involving context variation, needle guides, or freehand approaches yield superior skill acquisition and performance. This randomized controlled study aimed to evaluate these training strategies, specifically focusing on skill transfer among novices in ultrasound‐guided CVS. Material and Methods In this randomized controlled trial, 101 ultrasound novices were allocated into three training groups: context variation, needle‐guided, and freehand techniques. Participants completed a 1‐h training session performing ultrasound‐guided needle punctures on ballistic gel models. The context variation group alternated between needle‐guided and freehand techniques with varying visual constraints. After training, each participant completed four CVS transfer tests using a CVS simulator manikin, involving two needle‐guided and two freehand procedures, with differing placental positions. Blinded expert raters evaluated participant performance using a scoring system with established validity evidence. Statistical analyses included linear mixed‐effect models, ANOVA, and Pearson correlation coefficients.
Results
There were no significant differences in overall performance scores among the three training groups ( F [2, 92.0] = 0.06, p = 0.94). However, performance significantly improved during transfer tests when participants used a needle guide, irrespective of their initial training method ( F [1, 266.0] = 49.5, p < 0.001). Specifically, using a needle guide significantly enhanced scores for pre‐puncture ultrasound assessment ( t [370] = −4.1, p < 0.001), insertion site selection ( t [370] = −3.8, p < 0.001), sampling technique ( t [370] = −5.8, p < 0.001), and overall procedural performance ( t [370] = −5.8, p < 0.001).
Conclusions
Training approaches, including needle‐guided, freehand, and context variation techniques, did not differ significantly in their effect on learning ultrasound‐guided CVS. However, the consistent improvement in procedural performance with needle‐guided techniques suggests that incorporating needle guides into CVS training could promote safer practice for novice learners, particularly as clinical training opportunities become increasingly scarce.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Copenhagen Academy for Medical Education and Simulation (CAMES), Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark.
- Center of Fetal Medicine, Department of Gynecology, Fertility and Obstetrics, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark.
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
- Technical University of Denmark, Kongens Lyngby, Capital Region, Denmark.
- Department of Family & Community Medicine, University of Toronto, Toronto, Ontario, Canada.
ORCID-Profile: Vilma Johnsson, Olav B Petersen, Laerke Marijke Noerholk
Förderung
- AMEE
- NoVo Foundation
Zitieren
APA
Johnsson, V., Petersen, O. B., Svendsen, M. B. S., Kulasegaram, K., Nørgaard, L. N., Harmsen, L., Noerholk, L. M., Sundberg, K., & Tolsgaard, M. G. (2026). To guide or not to guide: A randomized study on the use of needle guide for chorionic villus sampling training. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.70108
Vancouver
Johnsson V, Petersen OB, Svendsen MBS, Kulasegaram K, Nørgaard LN, Harmsen L, et al. To guide or not to guide: A randomized study on the use of needle guide for chorionic villus sampling training. Acta Obstetricia et Gynecologica Scandinavica. 2026. doi:10.1111/aogs.70108
BibTeX
@article{Johnsson2026,
author = {Johnsson, Vilma and Petersen, Olav B and Svendsen, Morten Bo Søndergaard and Kulasegaram, Kulamakan and Nørgaard, Lone Nikoline and Harmsen, Lotte and Noerholk, Laerke Marijke and Sundberg, Karin and Tolsgaard, Martin G},
title = {To guide or not to guide: A randomized study on the use of needle guide for chorionic villus sampling training},
journal = {Acta Obstetricia et Gynecologica Scandinavica},
year = {2026},
doi = {10.1111/aogs.70108}
}
EUVIMED