Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial
Catheterization and Cardiovascular Interventions · 2025-10 · 106 (4) · 2252-2262
DOI: 10.1002/ccd.31733 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 30.07.2025. Verfasst von Wolfram Voelker und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine I-Cardiology, University Hospital Würzburg, Würzburg, Germany. Hauptthemen laut MEDLINE: Femoral Artery, Ultrasonography, Interventional, Cardiac Catheterization, Catheterization, Peripheral. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Ultrasound‐guided puncture of the common femoral artery (CFA) is assumed to be more precise than conventional techniques without ultrasound. However, previous comparative studies have shown partly contradictory results with regard to success of ultrasound‐guided puncture so that this method is not yet standard in transfemoral cardiac catheterization.
Aims
The PARFEM trial was performed to investigate whether an ultrasound‐assisted in‐plane technique using a needle guide could improve the precision of CFA puncture.
Methods
The study was conducted in 286 patients undergoing transfemoral cardiac catheterization. Patients were randomized 1:1, and femoral artery puncture was performed either using an ultrasound‐guided in‐plane technique with fluoroscopic marking of the center of the femoral head or a conventional approach. The primary endpoint was successful puncture of the CFA with the first attempt. In addition, the influence of the examiners' level of experience on puncture results was investigated.
Results
Primary successful puncture of the CFA was achieved more frequently in the ultrasound group than in the control group: 79.6% versus 55.6%, odds ratio 3.25 [95% CI: 1.92−5.23], p < 0.001. This favorable effect of ultrasound guidance was independent of the examiners' level of experience. The success rate of ultrasound‐guided sheath placement within the CFA was 97.2%, compared to 77.8% in the control group ( p < 0.01).
Conclusions
The PARFEM trial demonstrated that in‐plane ultrasound guidance can improve the precision of femoral puncture and reduce the occurrence of inadequate sheath placements. The results support the incorporation of this technique into standard practice for guiding transfemoral puncture. Trial Registration ClinicalTrials.gov Identifier: NCT06065943.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine I-Cardiology, University Hospital Würzburg, Würzburg, Germany.
- Caritas-Krankenhaus Bad Mergentheim, Bad Mergentheim, Germany.
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
- Department Clinical Research & Epidemiology, Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany.
ORCID-Profile: Wolfram Voelker, Guelmisal Gueder, Margarete Heinrichs, Ralph Kickuth, Wolfgang R Bauer, Peter Nordbeck, Stefan Frantz, Stefan Störk
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Voelker, W., Lachmann, M., Gueder, G., Bayik, A., Heinrichs, M., Kickuth, R., Bauer, W. R., Lengenfelder, B., Nordbeck, P., Frantz, S., & Störk, S. (2025). Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial. Catheterization and Cardiovascular Interventions, 106(4), 2252-2262. https://doi.org/10.1002/ccd.31733
Vancouver
Voelker W, Lachmann M, Gueder G, Bayik A, Heinrichs M, Kickuth R, et al. Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial. Catheterization and Cardiovascular Interventions. 2025;106(4):2252-2262. doi:10.1002/ccd.31733
BibTeX
@article{Voelker2025,
author = {Voelker, Wolfram and Lachmann, Maren and Gueder, Guelmisal and Bayik, Ahmed and Heinrichs, Margarete and Kickuth, Ralph and Bauer, Wolfgang R and Lengenfelder, Bjoern and Nordbeck, Peter and Frantz, Stefan and Störk, Stefan},
title = {Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
volume = {106},
number = {4},
pages = {2252--2262},
doi = {10.1002/ccd.31733}
}