The effectiveness and safety of temporary transvenous cardiac pacing leads placement into coronary sinus vein in patients with sick sinus syndrome
Annals of Noninvasive Electrocardiology · 2024
DOI: 10.1111/anec.13099 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Annals of Noninvasive Electrocardiology, 2024. Verfasst von Mingxian Chen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The Second Xiangya Hospital of Central South University, Changsha, China. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Coronary Sinus. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China, Provincial Natural Science Foundation of Hunan.
Abstract (Originalsprache)
Background
The temporary pacing lead routinely is placed into right ventricular (RV), which pose a risk of dislocation and cardiac perforation.
Objective
We aim to evaluate the effectiveness and safety of temporary transvenous cardiac pacing (TTCP) leads placement into the coronary sinus vein (CSV) in patients with sick sinus syndrome (SSS).
Methods
We investigated patients with SSS who underwent TTCP lead placement into the CSV under the guidance of X‐ray between January 2013 and May 2023. Patients were randomly divided into two groups: RV group ( n = 33) and CSV group ( n = 22). The ordinary passive bipolar electrodes were applied in both groups. In RV groups, electrodes were placed into RV. In CSV group, electrodes were placed into CSV. We evaluated the operation duration, fluoroscopic exposure, first‐attempt success rate of leads placement, pacing threshold, success rate of leads placement, rate of leads displacement, and complications.
Results
Compared with that in RV group, the procedure time, fluoroscopic exposure was significantly prolonged, while the first‐attempt success rate of lead placement was obviously increased in CSV group (both p < .05). Compared with that in RV group, the rate of leads displacement is lower in CSV group (both p < .05). There were three patients occurred cardiac perforation in RV group, but no cardiac perforation was reported in CSV group ( p > .05).
Conclusion
TTCP leads placement into the CSV is an effective and safe strategy in patients with SSS. It indicates a high rate of pacing effectiveness with low device replacement and complication rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, The Second Xiangya Hospital of Central South University, Changsha, China.
ORCID-Profile: Mingxian Chen, Zhihong Wu, Xuping Li
Förderung
- National Natural Science Foundation of China
- Provincial Natural Science Foundation of Hunan
Zitieren
APA
Chen, M., Wu, Z., Hu, L., Li, X., Yang, H., Liu, Z., Xiao, Y., Liu, Q., & Zhou, S. (2024). The effectiveness and safety of temporary transvenous cardiac pacing leads placement into coronary sinus vein in patients with sick sinus syndrome. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.13099
Vancouver
Chen M, Wu Z, Hu L, Li X, Yang H, Liu Z, et al. The effectiveness and safety of temporary transvenous cardiac pacing leads placement into coronary sinus vein in patients with sick sinus syndrome. Annals of Noninvasive Electrocardiology. 2024. doi:10.1111/anec.13099
BibTeX
@article{Chen2024,
author = {Chen, Mingxian and Wu, Zhihong and Hu, Lin and Li, Xuping and Yang, Hui and Liu, Zhenjiang and Xiao, Yichao and Liu, Qiming and Zhou, Shenghua},
title = {The effectiveness and safety of temporary transvenous cardiac pacing leads placement into coronary sinus vein in patients with sick sinus syndrome},
journal = {Annals of Noninvasive Electrocardiology},
year = {2024},
doi = {10.1111/anec.13099}
}
EUVIMED