EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Initial studies on the implanting sites of high and low ventricular septa using leadless cardiac pacemakers

Qiao-Yuan Li, Jian-Zeng Dong iD, Cheng-Jun Guo, Dong-Ping Fang, Xu Liu, Wen-Long Dai

Annals of Noninvasive Electrocardiology · 2023

DOI: 10.1111/anec.13068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Noninvasive Electrocardiology, 2023. Verfasst von Qiao-Yuan Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Ventricular Septum, Pacemaker, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To study the safety and electrical characteristics of various implanting sites of the Micra pacemaker.

Method

A total of 15 patients from Beijing Anzhen Hospital, Capital Medical University, were included, who were implanted with Micra leadless pacemakers and allocated to either the high ventricular septum group (eight patients) or the low ventricular septum group (seven patients) based on their individual patient factors and clinical conditions. The baseline of the patients, the implanting area, the electrocardiogram change after implantation, the implantation data, the threshold, R wave, impedance, and the date of the 1‐month follow‐up were then analyzed. With all of the data, the characteristics of different implantation sites of the Micra pacemaker were determined.

Results

Overall, the thresholds were low at implantation and remained stable over the 1‐, 3‐, 6‐month, 1‐, 2‐, 3‐, and 4‐year follow‐ups. On comparing the two groups, there was no difference in QRS duration at pacing (140.00 [40.00] ms vs. 179.00 [50.00] ms), threshold at implantation (0.38 [0.22] mV vs. 0.63 [1.00] mV), R wave at implantation ([10.85 ± 4.71] V vs. [7.26 ± 2.98] V), or impedance at implantation ([906.25 ± 162.39] Ω vs. [750.00 ± 173.40] Ω). While the difference in QRS duration between the two groups was not significant, the QRS duration of the high ventricular septum group exhibited a reduced tendency compared with that of the low ventricular group. The corrected QT interval during pacing exhibited a significant difference (440.00 [80.00] ms vs. 520.00 [100.00] ms; p < .05). For the 1‐, 3‐, 6‐month, 1‐, 2‐, 3‐, and 4‐year follow‐ups, there was no difference between the threshold of the high ventricular septum group and that of the low ventricular septum group ( p > .05).

Conclusion

High ventricular septum pacing appears to be a safe site for implantation of the Micra pacemaker. It could entail a shorter QRS duration at pacing and could be more physiological than low ventricular septum pacing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ventricular SeptumPacemaker, ArtificialHumansCardiac Pacing, ArtificialTreatment OutcomeElectrocardiography

Stichwörter der Autor:innen

Micracardiologyhigh ventricular septumimplanting sitesleadless pacemakerlow ventricular septum

Autor:innen und Institutionen

  • The Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

ORCID-Profile: Jian-Zeng Dong

Zitieren

APA

Li, Q. Y., Dong, J. Z., Guo, C. J., Fang, D. P., Liu, X., & Dai, W. L. (2023). Initial studies on the implanting sites of high and low ventricular septa using leadless cardiac pacemakers. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.13068

Vancouver

Li QY, Dong JZ, Guo CJ, Fang DP, Liu X, Dai WL. Initial studies on the implanting sites of high and low ventricular septa using leadless cardiac pacemakers. Annals of Noninvasive Electrocardiology. 2023. doi:10.1111/anec.13068

BibTeX
@article{Li2023,
  author = {Li, Qiao-Yuan and Dong, Jian-Zeng and Guo, Cheng-Jun and Fang, Dong-Ping and Liu, Xu and Dai, Wen-Long},
  title = {Initial studies on the implanting sites of high and low ventricular septa using leadless cardiac pacemakers},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2023},
  doi = {10.1111/anec.13068}
}
Kostenlos starten →