EUVIMEDEUVIMED entdecken
Crossref

Feasibility and safety of left bundle branch area pacing in patients with septal hypertrophy

Emine Özpak iD, Frederic Van Heuverswyn, Frank Timmermans, Jan De Pooter iD

Journal of Cardiovascular Electrophysiology · 2023

DOI: 10.1111/jce.16073 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Emine Özpak und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Ghent University Hospital, Ghent, Belgium. Hauptthemen laut MEDLINE: Ventricular Function, Left, Ventricular Septum. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Left bundle branch area pacing (LBBAP) aims to provide physiological ventricular activation during pacing. Left ventricular septal hypertrophy (LVSH) might be challenging for LBBAP due to the thickness of the interventricular septum and potential presence of septal scar. This study assesses the feasibility, safety, and outcome of LBBAP in patients with LVSH using primarily stylet‐driven leads (SDL).

Methods

Adult patients with LVSH who underwent LBBAP between March 2019 and November 2022 were enrolled. Baseline patient characteristics, procedural data and postprocedural results were collected. The feasibility of LBBAP in LVSH patients was compared to a cohort of LBBAP patients with normal septal wall thickness (NST).

Results

Seventeen LVSH and 133 NST patients underwent LBBAP with successful implantation achieved in 15 LVSH patients (88%). Mean implant depth was 17.2 ± 1.9 mm, with 53% proven left bundle branch (LBB) capture. Paced QRS duration (146 ± 14 ms) and V6 R‐wave peak time (V6 RWPT; 79 ± 20 ms) were comparable between patients with and without septal hypertrophy, although patients with NST had higher rates of proven LBB capture (71% vs. 53%). In LVSH pacing thresholds (0.6 ± 0.3 V at 0.4 ms) and R‐wave amplitude (13.9 ± 5.6 mV) were favorable and remained stable at follow‐up. At 12 months, 87% of patients had stable or improved left ventricular ejection fraction.

Conclusion

The results of the study indicate that LBBAP in patients with LVSH is safe and feasible and no lead‐related complications were observed despite a mean implant depth exceeding 15 mm. LBBAP using SDL results in favorable pacing and electrocardiographic characteristics in LVSH patients, comparable to patients with NST.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ventricular Function, LeftVentricular SeptumAdultHumansFeasibility StudiesStroke VolumeHypertrophy, Left VentricularElectrocardiographyCardiac Pacing, ArtificialBundle of HisTreatment Outcome

Stichwörter der Autor:innen

cardiac pacingcardiomyopathyfeasibilityleft bundle branch area pacingleft ventricular hypertrophy

Autor:innen und Institutionen

  • Department of Cardiology, Ghent University Hospital, Ghent, Belgium.

ORCID-Profile: Emine Özpak, Jan De Pooter

Zitieren

APA

Özpak, E., Van Heuverswyn, F., Timmermans, F., & De Pooter, J. (2023). Feasibility and safety of left bundle branch area pacing in patients with septal hypertrophy. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16073

Vancouver

Özpak E, Van Heuverswyn F, Timmermans F, De Pooter J. Feasibility and safety of left bundle branch area pacing in patients with septal hypertrophy. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.16073

BibTeX
@article{zpak2023,
  author = {Özpak, Emine and Van Heuverswyn, Frederic and Timmermans, Frank and De Pooter, Jan},
  title = {Feasibility and safety of left bundle branch area pacing in patients with septal hypertrophy},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2023},
  doi = {10.1111/jce.16073}
}
Kostenlos starten →