The performance and complications of long peripheral venous catheters: A retrospective single‐centre study
Acta Anaesthesiologica Scandinavica · 2024-11 · 68 (10) · 1463-1470
DOI: 10.1111/aas.14517 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Acta Anaesthesiologica Scandinavica, online erschienen am 26.08.2024. Verfasst von Julie Krath und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic and Vascular Surgery, Anaesthesia Section, Aarhus University Hospital, Aarhus N, Denmark. Hauptthemen laut MEDLINE: Catheterization, Peripheral, Device Removal. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Intravenous therapies are essential for hospitalised patients. The rapid dissemination of portable ultrasound machines has eased ultrasound‐guided intravenous access and facilitated increased use of long peripheral venous catheters (LPCs). This study aimed to evaluate the clinical performance and complications of LPCs.
Methods
Retrospective, observational single‐site study. Data from all consecutively inserted LPCs during a period of 18 months was evaluated. The primary endpoint was the all‐cause incidence rate of catheter removal. Secondary endpoints included specific reasons for the catheter removal and the associations between predefined characteristics of the patients, the infusions and the catheters with catheter failure.
Results
During the period, 751 PVCs were inserted in 457 patients. The reasons for catheter removal were recorded in 563 cases. The overall incidence rate of catheter removal was 95.8/1000 catheter days (95% CI 88.4–103.8). The median dwell time was 8 days (IQR 5–14), and the total dwell time was 6136 days. Catheter failure occurred in 283 (50.3%) cases, of which the most common cause was phlebitis ( n = 101, 17.9%). In multivariable analyses, the use of the cephalic vein was significantly associated with both all‐cause catheter failure ( p < .001) and catheter failure due to phlebitis ( p < .001). In multivariable analyses, vancomycin infusion was not significantly associated with all‐cause catheter failure (HR 1.15 (0.55–2.42), p = .71) or catheter failure due to phlebitis (HR 1.49 (0.49–4.53), p = .49).
Conclusion
The overall incidence rate of catheter removal was 95.8/1000 catheter days, and the most common causes of catheter failure were phlebitis, infiltration and unintended catheter removal. The use of the cephalic vein was significantly associated with catheter failure in multivariable analyses. We did not find an association between vancomycin infusion and catheter failure in multivariable analyses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiothoracic and Vascular Surgery, Anaesthesia Section, Aarhus University Hospital, Aarhus N, Denmark.
- Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark.
- Department of Intensive Care Medicine, Aarhus University Hospital, Aarhus N, Denmark.
Zitieren
APA
Krath, J., Fredskilde, J., Christensen, S. K., Baltsen, C. D., Valentin, K., Offersen, R., & Juhl-Olsen, P. (2024). The performance and complications of long peripheral venous catheters: A retrospective single‐centre study. Acta Anaesthesiologica Scandinavica, 68(10), 1463-1470. https://doi.org/10.1111/aas.14517
Vancouver
Krath J, Fredskilde J, Christensen SK, Baltsen CD, Valentin K, Offersen R, et al. The performance and complications of long peripheral venous catheters: A retrospective single‐centre study. Acta Anaesthesiologica Scandinavica. 2024;68(10):1463-1470. doi:10.1111/aas.14517
BibTeX
@article{Krath2024,
author = {Krath, Julie and Fredskilde, Jesper and Christensen, Simone Krogh and Baltsen, Cecilie Dahl and Valentin, Kamilla and Offersen, Ryan and Juhl-Olsen, Peter},
title = {The performance and complications of long peripheral venous catheters: A retrospective single‐centre study},
journal = {Acta Anaesthesiologica Scandinavica},
year = {2024},
volume = {68},
number = {10},
pages = {1463--1470},
doi = {10.1111/aas.14517}
}
EUVIMED