A 240 Elements Matrix Probe with Aberration Mask for 4D Carotid Artery Computational Ultrasound Imaging
IEEE Transactions on Ultrasonics · 2025
DOI: 10.1109/tuson.2025.3648199 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, 2025. Verfasst von Yuyang Hu und 9 weiteren Autor:innen. Hauptthemen laut MEDLINE: Ultrasonography, Carotid Arteries, Imaging, Three-Dimensional, Carotid Arteries. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek.
Abstract (Originalsprache)
Three-dimensional ultrasound provides enhanced visualization of the carotid artery (CA) anatomy and volumetric flow, offering improved accuracy for cardiovascular diagnosis and monitoring. However, fully populated matrix transducers with large apertures are complex and costly to implement. Computational ultrasound imaging (cUSi) offers a promising alternative by enabling simplified hardware design through modelbased reconstruction and spatial field encoding. In this work, we present a 3-D cUSi system tailored for CA imaging, consisting of a 240-element matrix probe with a $40 \,\, \times \,\, 24~ {\mathrm {mm}}^{2}$ large aperture and a spatial encoding mask. We describe the system's design, characterization, and image reconstruction. Phantom experiments show that computational reconstruction using matched filtering (MF) significantly improves volumetric image quality over delay-and-sum (DAS), with spatial encoding enhancing lateral resolution at the cost of reduced contrast ratio (CR). Least-squares with QR (LSQR)-based reconstruction was demonstrated to further improve resolution and suppress artifacts. Using both Hadamard and 16-angle plane wave transmission schemes, the system achieved high-resolution images with reasonable contrast, supporting the feasibility of 4-D CA imaging applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Zitieren
APA
Hu, Y., Brown, M., Dogan, D., Bulot, M., Cheppe, M., Ferin, G., Leus, G., van der Steen, A. F. W., Kruizinga, P., & Bosch, J. G. (2025). A 240 Elements Matrix Probe with Aberration Mask for 4D Carotid Artery Computational Ultrasound Imaging. IEEE Transactions on Ultrasonics. https://doi.org/10.1109/tuson.2025.3648199
Vancouver
Hu Y, Brown M, Dogan D, Bulot M, Cheppe M, Ferin G, et al. A 240 Elements Matrix Probe with Aberration Mask for 4D Carotid Artery Computational Ultrasound Imaging. IEEE Transactions on Ultrasonics. 2025. doi:10.1109/tuson.2025.3648199
BibTeX
@article{Hu2025,
author = {Hu, Yuyang and Brown, Michael and Dogan, Didem and Bulot, Mahe and Cheppe, Maxime and Ferin, Guillaume and Leus, Geert and van der Steen, Antonius F W and Kruizinga, Pieter and Bosch, Johannes G},
title = {A 240 Elements Matrix Probe with Aberration Mask for 4D Carotid Artery Computational Ultrasound Imaging},
journal = {IEEE Transactions on Ultrasonics},
year = {2025},
doi = {10.1109/tuson.2025.3648199}
}
EUVIMED