EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasound Speckle Decorrelation Analysis‐Based Velocimetry for 3D‐Velocity‐Components Measurement Using a 1D Transducer Array

Yongchao Wang, Yetao He, Wenkai Chen, Jiyong Tan, Jianbo Tang iD

Advanced Science · 2024

DOI: 10.1002/advs.202401173 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, 2024. Verfasst von Yongchao Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Sh…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Rheology, Carotid Arteries, Transducers. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shenzhen Science and Technology Innovation Committee, National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound velocimetry has been widely used for blood flow imaging. However, the flow measurements are constrained to resolve the in‐plane 2D flow components when using a 1D transducer array. In this work, an ultrasound speckle decorrelation analysis‐based velocimetry (3C‐vUS) is proposed for 3D velocity components measurement using a 1D transducer array. The 3C‐vUS theory is first derived and validated with numerical simulations and phantom experiments. The in vivo testing results show that 3C‐vUS can accurately measure the blood flow 3D‐velocity‐components of the human carotid artery at arbitrary probe‐to‐vessel angles throughout the cardiac cycle. With such capability, the 3C‐vUS will alleviate the requirement of operators and promote disease screening for blood flow‐related disorders.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingRheologyCarotid ArteriesTransducersImaging, Three-DimensionalUltrasonographyHumansBlood Flow Velocity

Stichwörter der Autor:innen

3D‐velocity‐componentsblood flow imagingdynamic analysisultrasound velocimetry

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, ShenZhen, Guangdong, 518055, China.

ORCID-Profile: Jianbo Tang

Förderung

  • Shenzhen Science and Technology Innovation Committee
  • National Natural Science Foundation of China
  • Ministry of Science and Technology of the People's Republic of China
  • Guangdong Science and Technology Department
  • Guangdong Provincial Key Laboratory of Advanced Biomaterials
  • Guangdong Provincial Department of Science and Technology

Zitieren

APA

Wang, Y., He, Y., Chen, W., Tan, J., & Tang, J. (2024). Ultrasound Speckle Decorrelation Analysis‐Based Velocimetry for 3D‐Velocity‐Components Measurement Using a 1D Transducer Array. Advanced Science. https://doi.org/10.1002/advs.202401173

Vancouver

Wang Y, He Y, Chen W, Tan J, Tang J. Ultrasound Speckle Decorrelation Analysis‐Based Velocimetry for 3D‐Velocity‐Components Measurement Using a 1D Transducer Array. Advanced Science. 2024. doi:10.1002/advs.202401173

BibTeX
@article{Wang2024,
  author = {Wang, Yongchao and He, Yetao and Chen, Wenkai and Tan, Jiyong and Tang, Jianbo},
  title = {Ultrasound Speckle Decorrelation Analysis‐Based Velocimetry for 3D‐Velocity‐Components Measurement Using a 1D Transducer Array},
  journal = {Advanced Science},
  year = {2024},
  doi = {10.1002/advs.202401173}
}
Kostenlos starten →