Optimization of TOF and DOI Performance in a Multi-Resolution Detector for Brain-Dedicated PET
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-03 · 10 (3) · 380-390
DOI: 10.1109/trpms.2025.3581111 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-03. Verfasst von Sheng Huang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
Brain-dedicated positron emission tomography (PET) systems require detectors with high spatial resolution, depth-of-interaction (DOI) resolution, and time-of-flight (TOF) resolution. This work presents the development and optimization of a multi-resolution detector module for brain PET imaging, with a focus on enhancing DOI and TOF performance. The detector module consists of four detector blocks, each featuring a two-layer lutetium yttrium oxyorthosilicate (LYSO) crystal array with different pixel sizes (top layer: 16 × 16 array of 1.53 × 1.53 × 5 mm3 crystals; bottom layer: 8 × 8 array of 3 × 3 × 15 mm3 crystals), forming an effective area of 51.6 × 51.6 mm2. To improve DOI resolution, we introduced a q-value method which achieved a DOI resolution of 3.03 mm for the bottom layer crystals. TOF resolution was optimized through timing correction techniques incorporating DOI information and multiple timestamps. For top layer events, the event time was determined using a charge-integration (QDC)-weighted average of the first three timestamps. For bottom layer events, a joint pmax&tdoi correction was applied following a QDC-4th power weighted average of the first three timestamps. The coincidence time resolution (CTR) achieved 442 ps for top-top, 370 ps for top-bottom, and 259 ps for bottom-bottom coincidences. Removing inter-crystal scatter (ICS) events from the bottom layer further improved the bottom-bottom CTR to 245 ps. The intrinsic spatial resolution (ISR) reached 0.93 mm for the top layer and 1.77 mm for the bottom layer after ICS events removal. By achieving high DOI, CTR and ISR, this detector module demonstrates significant potential for integration into next-generation, high-performance brain-dedicated PET scanners.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Huang, S., Jiang, X., Chen, Z., Zeng, X., Huang, W., Yang, H., He, W., Niu, M., Wu, J., Wei, Q., & Gu, Z. (2026). Optimization of TOF and DOI Performance in a Multi-Resolution Detector for Brain-Dedicated PET. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(3), 380-390. https://doi.org/10.1109/trpms.2025.3581111
Vancouver
Huang S, Jiang X, Chen Z, Zeng X, Huang W, Yang H, et al. Optimization of TOF and DOI Performance in a Multi-Resolution Detector for Brain-Dedicated PET. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(3):380-390. doi:10.1109/trpms.2025.3581111
BibTeX
@article{Huang2026,
author = {Huang, Sheng and Jiang, Xiaolong and Chen, Zhang and Zeng, Xiangtao and Huang, Wenjie and Yang, Hang and He, Wen and Niu, Ming and Wu, Jing and Wei, Qingyang and Gu, Zheng},
title = {Optimization of TOF and DOI Performance in a Multi-Resolution Detector for Brain-Dedicated PET},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {3},
pages = {380--390},
doi = {10.1109/trpms.2025.3581111}
}
EUVIMED