EUVIMEDEUVIMED entdecken
Crossref

Extraction of Cardiac Time Intervals From a Radar Kinetocardiogram for Continuous Blood Pressure Monitoring

Jinke Xie, Juhua Huang, Hongtao Wan, Chongnan Xu, Xuetao Zuo

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 4008717-4008717

DOI: 10.1109/tim.2026.3699668 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Jinke Xie und 4 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Project “Development of a Microwave-Based Noncontact Respiration, Heart Rate, and Blood Pressure Monitoring Device” commissioned by Shenzhen Mindray Bio-Medica….

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Noncontact blood pressure (BP) monitoring remains challenging. Conventional pulse-wave–based approaches rely on fine-grained waveform morphology and are vulnerable to respiratory interference. Deep learning can improve accuracy, yet often lacks physiological interpretability and requires large training datasets. This work proposes a radar-kinetocardiogram (RKG)-based BP monitoring method that does not rely on deep learning. To suppress respiratory interference, we introduce Adaptive Respiratory-Harmonic Variational Mode Extraction (ARH-VME) effectively removes respiratory fundamentals and harmonics while preserving key cardiac components. By extracting cardiac time intervals (CTIs) from the RKG and estimating BP primarily from these temporal markers, the method markedly reduces dependence on detailed waveform morphology and improves robustness. In a clinical study with 25 subjects, the approach achieved a mean error (ME), mean absolute error (MAE), and standard deviation (SD) of 0.3 (5.72) $\pm ~6.44$ mmHg for systolic BP (SBP) and −0.4 (3.02) $\pm ~3.6$ mmHg for diastolic BP (DBP) under static conditions, falling within the numerical limits commonly referenced from the AAMI standard and demonstrated stable performance over 40–100 cm sensing distances as well as incidence angles up to 45°. Cross-platform generalizability was further validated on an independent public dataset. These results indicate a physiologically interpretable and robust pathway for practical, noncontact BP monitoring.

Förderung

  • Project “Development of a Microwave-Based Noncontact Respiration, Heart Rate, and Blood Pressure Monitoring Device” commissioned by Shenzhen Mindray Bio-Medica…

Zitieren

APA

Xie, J., Huang, J., Wan, H., Xu, C., & Zuo, X. (2026). Extraction of Cardiac Time Intervals From a Radar Kinetocardiogram for Continuous Blood Pressure Monitoring. IEEE Transactions on Instrumentation and Measurement, 75, 4008717-4008717. https://doi.org/10.1109/tim.2026.3699668

Vancouver

Xie J, Huang J, Wan H, Xu C, Zuo X. Extraction of Cardiac Time Intervals From a Radar Kinetocardiogram for Continuous Blood Pressure Monitoring. IEEE Transactions on Instrumentation and Measurement. 2026;75:4008717-4008717. doi:10.1109/tim.2026.3699668

BibTeX
@article{Xie2026,
  author = {Xie, Jinke and Huang, Juhua and Wan, Hongtao and Xu, Chongnan and Zuo, Xuetao},
  title = {Extraction of Cardiac Time Intervals From a Radar Kinetocardiogram for Continuous Blood Pressure Monitoring},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {4008717--4008717},
  doi = {10.1109/tim.2026.3699668}
}
Kostenlos starten →