EUVIMEDEUVIMED entdecken
Crossref

Continuous Right Ventricular Pressure Monitoring in Cardiac Surgery

André Denault, Etienne J Couture, Tjorvi Perry, Elena Saade, Alexander Calderone, Yu Hao Zeng, Daniel Scherb, Kevin Moses, Cristhian Potes, Ali Hammoud, William Beaubien-Souligny, Mahsa Elmi-Sarabi und 6 weitere

Journal of Cardiothoracic and Vascular Anesthesia · 2024-08 · 38 (8) · 1673-1682

DOI: 10.1053/j.jvca.2024.04.025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2024-08. Verfasst von André Denault und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada. Electronic address: andre.denault@umontreal…. Hauptthemen laut MEDLINE: Cardiac Surgical Procedures, Monitoring, Intraoperative, Ventricular Dysfunction, Right. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Edwards Lifesciences Corporation, Montreal Heart Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Right ventricular (RV) dysfunction in cardiac surgery can lead to RV failure, which is associated with increased morbidity and mortality. Abnormal RV function can be identified using RV pressure monitoring. The primary objective of the study is to determine the proportion of patients with abnormal RV early to end-diastole diastolic pressure gradient (RVDPG) and abnormal RV end-diastolic pressure (RVEDP) before initiation and after cardiopulmonary bypass (CPB) separation. The secondary objective is to evaluate if RVDPG before CPB initiation is associated with difficult and complex separation from CPB, RV dysfunction, and failure at the end of cardiac surgery. DESIGN: Prospective study. SETTING: Tertiary care cardiac institute. PARTICIPANTS: Cardiac surgical patients. INTERVENTION: Cardiac surgery. MEASUREMENTS AND MAIN RESULTS: Automated electronic quantification of RVDPG and RVEDP were obtained. Hemodynamic measurements were correlated with cardiac and extracardiac parameters from transesophageal echocardiography and postoperative complications. Abnormal RVDPG was present in 80% of the patients (n = 105) at baseline, with a mean RVEDP of 14.2 ± 3.9 mmHg. Patients experienced an RVDPG > 4 mmHg for a median duration of 50.2% of the intraoperative period before CPB initiation and 60.6% after CPB separation. A total of 46 (43.8%) patients had difficult/complex separation from CPB, 18 (38.3%) patients had RV dysfunction, and 8 (17%) had RV failure. Abnormal RVDPG before CPB was not associated with postoperative outcome. CONCLUSION: Elevated RVDPG and RVEDP are common in cardiac surgery. RVDPG and RVEDP before CPB initiation are not associated with RV dysfunction and failure but can be used to diagnose them.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Surgical ProceduresMonitoring, IntraoperativeVentricular Dysfunction, RightHumansMaleProspective StudiesFemaleAgedMiddle AgedVentricular PressureCardiopulmonary BypassVentricular Function, RightEchocardiography, Transesophageal

Stichwörter der Autor:innen

cardiac anesthesiologycardiac surgeryhemodynamichemodynamic monitoringright ventricleright ventricular pressure monitoring

Autor:innen und Institutionen

  • Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada. Electronic address: andre.denault@umontreal.ca.
  • Department of Anesthesiology, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Quebec City, Quebec, Canada.
  • Department of Anesthesiology, University of Minnesota, Minneapolis, MN, USA.
  • Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada.
  • Departments of Medicine and of Family Medicine, Jewish General Hospital, McGill University Health Centre, Montreal, Quebec, Canada.
  • Edwards Lifesciences, Irvine, CA, USA.

Förderung

  • Edwards Lifesciences Corporation
  • Montreal Heart Institute

Zitieren

APA

Denault, A., Couture, E. J., Perry, T., Saade, E., Calderone, A., Zeng, Y. H., Scherb, D., Moses, K., Potes, C., Hammoud, A., Beaubien-Souligny, W., Elmi-Sarabi, M., Grønlykke, L., Lamarche, Y., Lebon, J. S., Rousseau-Saine, N., Desjardins, G., & Rochon, A. (2024). Continuous Right Ventricular Pressure Monitoring in Cardiac Surgery. Journal of Cardiothoracic and Vascular Anesthesia, 38(8), 1673-1682. https://doi.org/10.1053/j.jvca.2024.04.025

Vancouver

Denault A, Couture EJ, Perry T, Saade E, Calderone A, Zeng YH, et al. Continuous Right Ventricular Pressure Monitoring in Cardiac Surgery. Journal of Cardiothoracic and Vascular Anesthesia. 2024;38(8):1673-1682. doi:10.1053/j.jvca.2024.04.025

BibTeX
@article{Denault2024,
  author = {Denault, André and Couture, Etienne J and Perry, Tjorvi and Saade, Elena and Calderone, Alexander and Zeng, Yu Hao and Scherb, Daniel and Moses, Kevin and Potes, Cristhian and Hammoud, Ali and Beaubien-Souligny, William and Elmi-Sarabi, Mahsa and Grønlykke, Lars and Lamarche, Yoan and Lebon, Jean-Sébastien and Rousseau-Saine, Nicolas and Desjardins, Georges and Rochon, Antoine},
  title = {Continuous Right Ventricular Pressure Monitoring in Cardiac Surgery},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2024},
  volume = {38},
  number = {8},
  pages = {1673--1682},
  doi = {10.1053/j.jvca.2024.04.025}
}
Kostenlos starten →