Optoacousto-Fluidics Based Optical Rotation Measure for Blood Glucose Sensing
IEEE Transactions on Biomedical Engineering · 2025
DOI: 10.1109/tbme.2025.3566940 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2025. Verfasst von Swathi Padmanabhan und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Blood Glucose, Photoacoustic Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Ministry of Education, IISc Seed Grant, IISc, Bengaluru.
Abstract (Originalsprache)
SIGNIFICANCE: Glucose sensing in deep tissue is challenging due to high light scattering and the optical properties of tissue constituents. OBJECTIVE: We present a novel approach that integrates polarized light with optoacousto-fluidics based glucose sensing. METHODS: A custom microfluidic chip mimicking blood vessel dimensions was developed to measure optical rotation via optoacoustic detection using polarized light (vertical and circular) at 1560 nm (near-infrared). The system reduces sample volume requirements while maintaining high sensitivity and accuracy. Experiments were performed using serum-like and human blood samples at a depth of 2 mm through whole blood. Flow dynamics was varied to assess their impact on measurement accuracy. Proof-of-concept studies included samples from diabetic and healthy volunteers. RESULTS: Depth-resolved optoacoustic signals enabled accurate optical rotation quantification for glucose detection. Variations in flow velocity showed no significant effect, confirming system reliability under dynamic conditions. The system achieved a detection limit of 50 mg/dL in serum samples. Classification of diabetic and healthy samples reached an 88% prediction accuracy. CONCLUSION: This work demonstrates a low-volume, high-sensitivity method for glucose detection using polarized light and optoacousto-fluidics, with potential for real-time, non-invasive monitoring at tissue depths of 2-3 mm. It lays the foundation for advancing optical rotation-based glucose detection methodologies with significant implications for in-vivo sensing (at depths of 2-3 mm in skin).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Ministry of Education
- IISc Seed Grant
- IISc, Bengaluru
Zitieren
APA
Padmanabhan, S., Shashank, S. A., Srinivasan, R., & Prakash, J. (2025). Optoacousto-Fluidics Based Optical Rotation Measure for Blood Glucose Sensing. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2025.3566940
Vancouver
Padmanabhan S, Shashank SA, Srinivasan R, Prakash J. Optoacousto-Fluidics Based Optical Rotation Measure for Blood Glucose Sensing. IEEE Transactions on Biomedical Engineering. 2025. doi:10.1109/tbme.2025.3566940
BibTeX
@article{Padmanabhan2025,
author = {Padmanabhan, Swathi and Shashank, Sarikonda Aryan and Srinivasan, Rajesh and Prakash, Jaya},
title = {Optoacousto-Fluidics Based Optical Rotation Measure for Blood Glucose Sensing},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2025},
doi = {10.1109/tbme.2025.3566940}
}
EUVIMED