EUVIMEDEUVIMED entdecken
Crossref

Robust Photoacoustic Eigen Waveform Analysis for Characterization of Cancellous Bone

Ting Feng, Caicai Huang, Chenyin Ni, Yejing Xie, Yihan Zhu, Chengcheng Liu, Qian Cheng, Dean Ta

IEEE Transactions on Biomedical Engineering · 2025

DOI: 10.1109/tbme.2025.3544876 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2025. Verfasst von Ting Feng und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Photoacoustic Techniques, Cancellous Bone, Signal Processing, Computer-Assisted, Image Processing, Computer-Assisted. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Noninvasive photoacoustic (PA) imaging techniques afford abundant microstructure information for the diagnosis and therapeutic monitoring of diseases. However, their use for bone tissue imaging is challenging owing to the high scattering and attenuation properties of bone tissue. The PA signal waveforms inherently contain optical and ultrasonic properties related to bone health. This study entailed the development of a robust, compensation-free PA eigen waveform analysis (PEWA) method for characterizing high-scattering cancellous bone in transmission mode. METHODS: Numerical simulations and experimental studies were conducted on cancellous bone models with various bone mineral densities (BMDs), optical, and ultrasonic properties. The resulting PA signals were analyzed using PEWA method, facilitating the quantification of parameters related to bone conditions, such as the exponential growth coefficient. RESULTS: The simulation results indicate that bone specimens with lower BMDs have lower exponential growth coefficients. Furthermore, we found that the exponential growth coefficient has better robustness and stability than conventional amplitude-based parameter. The experimental findings from animal cancellous bone tissues ex vivo with different BMDs were in close agreement with the simulation results, thus demonstrating that the PEWA method can perform BMD assessments for cancellous bone. SIGNIFICANCE: Considering that PA measurements are nonionizing and noninvasive and have sufficient penetration in both nonorganic (bone matrix) and organic tissues (bone marrow), the proposed compensation-free, PEWA bone evaluation method has the potential to facilitate early and rapid clinical assessment of osteoporosis. The proposed approach has considerable applicability in the domains of miniaturization equipment intelligent evaluation of bone health.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Photoacoustic TechniquesCancellous BoneSignal Processing, Computer-AssistedImage Processing, Computer-AssistedAnimalsBone DensityComputer SimulationWavelet AnalysisPhantoms, ImagingAlgorithms

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Feng, T., Huang, C., Ni, C., Xie, Y., Zhu, Y., Liu, C., Cheng, Q., & Ta, D. (2025). Robust Photoacoustic Eigen Waveform Analysis for Characterization of Cancellous Bone. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2025.3544876

Vancouver

Feng T, Huang C, Ni C, Xie Y, Zhu Y, Liu C, et al. Robust Photoacoustic Eigen Waveform Analysis for Characterization of Cancellous Bone. IEEE Transactions on Biomedical Engineering. 2025. doi:10.1109/tbme.2025.3544876

BibTeX
@article{Feng2025,
  author = {Feng, Ting and Huang, Caicai and Ni, Chenyin and Xie, Yejing and Zhu, Yihan and Liu, Chengcheng and Cheng, Qian and Ta, Dean},
  title = {Robust Photoacoustic Eigen Waveform Analysis for Characterization of Cancellous Bone},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2025},
  doi = {10.1109/tbme.2025.3544876}
}
Kostenlos starten →