EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of non‐contact foreign body imaging base on photoacoustic signal intensity measurement

Andreas Setiawan iD, Chia-Yi Huang, Mitrayana Mitrayana

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14230 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Andreas Setiawan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Universitas Kristen Satya Wacana, Salatiga, Indonesia. Hauptthemen laut MEDLINE: Photoacoustic Techniques, Foreign Bodies. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Direktorat Penelitian, Tim Peningkatan Reputasi World Class University and Kantor Jaminan Mutu Universitas Gadjah Mada, Universitas Kristen Satya Wacana, Salatiga, Indonesia and Tunghai University, Taichung, Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

It is challenging to visually identify tiny and concealed foreign objects within the body due to their small size and subcutaneous location while they can cause infections.

Methods

A non‐contact photoacoustic system based on Rosencwaig‐Gersho photoacoustic theory and dual modulator method is developed for detecting foreign objects in meat.

Result

The experiments conducted validate the successful development of this measurement technique with 10 μm spatial resolution and its corresponding mathematical model, demonstrating an 11% Mean Absolute Percentage Error (MAPE) in comparison to the experimental results. Dual modulator successfully regulates laser energy at MPE limit.

Conclusion

The utilization of non‐contact photoacoustic signal intensity measurements enables the identification of foreign objects within the body. Further, the application of mathematical modelling can validate the measurement outcomes. These findings serve as a foundation for creating an affordable and straightforward foreign body detector.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Photoacoustic TechniquesForeign BodiesHumansImage Processing, Computer-AssistedPhantoms, ImagingModels, TheoreticalSignal Processing, Computer-AssistedAnimals

Stichwörter der Autor:innen

Rosencwaig‐Gersho theoryforeign bodyphotoacoustic imaging

Autor:innen und Institutionen

  • Department of Physics, Universitas Kristen Satya Wacana, Salatiga, Indonesia.
  • Department of Applied Physics, Tunghai University, Taichung, Taiwan R.O.C.
  • Department of Physics, Faculty of Mathematics and Natural Sciences Universitas Gadjah MadaSekip Utara Bulaksumur, Yogyakarta, Indonesia.

ORCID-Profile: Andreas Setiawan

Förderung

  • Direktorat Penelitian, Tim Peningkatan Reputasi World Class University and Kantor Jaminan Mutu Universitas Gadjah Mada
  • Universitas Kristen Satya Wacana, Salatiga, Indonesia and Tunghai University, Taichung, Taiwan

Zitieren

APA

Setiawan, A., Huang, C. Y., & Mitrayana, M. (2024). Development of non‐contact foreign body imaging base on photoacoustic signal intensity measurement. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14230

Vancouver

Setiawan A, Huang CY, Mitrayana M. Development of non‐contact foreign body imaging base on photoacoustic signal intensity measurement. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14230

BibTeX
@article{Setiawan2024,
  author = {Setiawan, Andreas and Huang, Chia-Yi and Mitrayana, Mitrayana},
  title = {Development of non‐contact foreign body imaging base on photoacoustic signal intensity measurement},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14230}
}
Kostenlos starten →